Implementation and Validation of an Inline Spiking Model for Assessing Viral Clearance in Continuous Virus Filtration Process.
Tiandan Xu, Shan Yang, Shanshan Wang, Yixing Chen, Ziyu Wang, Tianle Qian, Daguo Yang, Yuanyuan Chen,
Downstream Process Development (DSPD), WuXi Biologics (Shanghai) Co. Ltd., Shanghai, China. · WuXi Biologics Biosafety Testing (Suzhou) Co. Ltd., Suzhou, Jiangsu, China.
Key points
From the paper's conclusion- The results demonstrate the robustness of CVF under a cumulative sequence of process challenges and provide a practical platform for future viral clearance studies.
Abstract
Current viral clearance validation for continuous virus filtration (CVF) remains technically challenging, highlighting the need for robust small-scale models. To address this need, we established a small-scale CVF model on an ÄKTA system featuring inline virus spiking, in which high-titer virus was introduced during the early and mid-to-late stages of filtration. A virus-protein pre-treatment approach was also developed to enable stable and efficient inline spiking under very low-flux conditions. The model supported continuous operation of a Viresolve Pro virus filter for 203 h (8.5 days), achieving a volumetric throughput exceeding 4400 L/m2 and a mass throughput exceeding 42,000 g/m2. Across six spiking stages, a cumulative load of ≥ 2 × 108 plaque-forming units (PFU) of minute virus of mice (MVM) was introduced. The virus filter consistently maintained parvovirus clearance with logarithmic reduction values (LRVs) > 4, independent of load variations, low flux and pressure, process pauses, extended filtration duration, and high throughput. This small-scale CVF model was designed to explore the boundaries of the design space. The results demonstrate the robustness of CVF under a cumulative sequence of process challenges and provide a practical platform for future viral clearance studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Novel Scale-Down Model Development and Viral Clearance Validation for the Periodic Counter-Current Continuous Capture Chromatography.Biotechnology and bioengineering · 2026
- Continuous Concentration of an Enveloped Virus Using Multi-Pass Tangential Flow Filtration.Biotechnology and bioengineering · 2026
- VDisk: A Microfluidic Cartridge for Automated and Reproducible Label-Free Isolation of Extracellular Vesicles from PlasmabioRxiv · 2026
- The effects of membrane structure and filtration conditions on virus filtrationJournal of Membrane Science · 2025
- A Platform Approach to Continuous mRNA Purification.Biotechnology and bioengineering · 2026
- From Removal to Reliability: A New Perspective on Membrane-Based Virus Control in Household Water TreatmentACS ES&T Water · 2026