Brachytherapy

Clinical dosimetry for nose vestibule carcinoma interventional radiotherapy (modern brachytherapy): 15 year's experience from a large tertiary center.

Bruno Fionda, Enrico Rosa, Claudio Parrilla, Mario Rigante, Elisa Placidi, Valentina Lancellotta, Stefano Settimi, Pierpaolo Dragonetti,

UOC Degenze di Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini e Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy. · UOC Fisica per le Scienze della Vita, Dipartimento di Diagnostica per Immagini e Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy; Università Cattolica del Sacro Cuore, Rome, Italy. Electronic address: enrico.rosa@unicatt.it.

Observational

Key points

From the paper's conclusion
  • IRT for nose vestibule carcinoma evolved toward the treatment of larger and more complex targets while maintaining, and progressively improving, dosimetric quality. Overall, these findings suggest a progressive refinement of implantation and treatment-planning techniques with accumulated institutional experience.

Abstract

PURPOSE: Nose vestibule carcinoma is a rare and often under-recognized clinical entity, with specific anatomical features that make treatment planning particularly challenging. Interventional radiotherapy (IRT, brachytherapy) represents a well-established organ-preserving treatment option, but its dosimetric characteristics remain insufficiently described. This study aimed to evaluate the temporal evolution of IRT for nose vestibule carcinoma over a 15-year period, focusing on implant technique, procedural complexity, and dosimetric parameters. METHODS AND MATERIALS: Patients with nose vestibule carcinoma treated with high-dose-rate IRT at a single institution between 2012 and 2026 were retrospectively analyzed. Clinical target volume, number and anatomical distribution of catheters, and dose non-uniformity ratio were collected. Temporal trends and exploratory relationships between target volume, implant geometry, and dose heterogeneity were descriptively evaluated. RESULTS: Eighty-five patients were included. The mean clinical target volume was 25 cc (range: 2.0-98.0 cc), while the mean number of implanted catheters was 10 (range: 3-25). The mean dose non-uniformity ratio was 0.53 (range: 0.30-0.78). Despite increasing implant complexity, the dose non-uniformity ratio progressively decreased, suggesting improved dose modulation and refinement of implant geometry. CONCLUSIONS: IRT for nose vestibule carcinoma evolved toward the treatment of larger and more complex targets while maintaining, and progressively improving, dosimetric quality. Overall, these findings suggest a progressive refinement of implantation and treatment-planning techniques with accumulated institutional experience.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers