Journal of plastic, reconstructive & aesthetic surgery : JPRAS

Extended reality-assisted preoperative simulation for deep inferior epigastric perforator flap harvest improves interobserver reliability of perforator identification.

Hakuba Takeishi, Kazunori Watanabe, Ryo Shimoda, Yoshichika Yasunaga, Maki Sugimoto, Jun Araki

Division of Plastic and Reconstructive Surgery, Shizuoka Cancer Center Hospital, Shizuoka, Japan; Department of Plastic and Reconstructive Surgery, The University of Tokyo, Tokyo, Japan. · Department of Diagnostic Radiology, Shizuoka Cancer Center Hospital, Shizuoka, Japan.

Computational

Key points

From the paper's conclusion
  • XR visualization improved interobserver agreement and reduced experience-related variability in DIEP vascular assessment, with perforator counts aligning more closely with the intraoperative findings. XR may be a useful adjunct to preoperative planning and surgical education; however, further studies are needed to establish its impact on operative performance and patient outcomes.

Abstract

BACKGROUND: Deep inferior epigastric perforator (DIEP) flap reconstruction requires precise understanding of the highly variable vascular anatomy. Although computed tomography angiography (CTA) facilitates preoperative planning, conventional two-dimensional (2D) images can be difficult to interpret, particularly for inexperienced surgeons. Extended reality (XR) enables immersive three-dimensional visualization; however, its impact on anatomical interpretation and interobserver reliability continues to be unclear. We evaluated whether XR improves DIEP flap assessment compared with 2D images. METHODS: Bilateral DIEPs from five patients (10 hemi-abdomens) who underwent preoperative CTA were analyzed. Four junior and three senior plastic surgeons evaluated perforator counts and DIEP-superficial inferior epigastric vein (DIEP-SIEV) linking vessels using either 2D images or XR visualization. Interobserver reliability was assessed using intraclass correlation coefficients (ICC) with 95% confidence intervals. Agreement between the junior and senior surgeons under each visualization modality was evaluated using the Bland-Altman analysis. In a separate analysis of the five hemi-abdomens from which the DIEP flaps were harvested, preoperative perforator counts were compared with the number of perforators that were identified and selected intraoperatively for flap harvest. RESULTS: On 2D images, junior surgeons identified significantly more perforators than seniors (89.0 ± 8.16 vs. 72.6 ± 3.05, P = 0.023), whereas no significant difference was observed in case of XR images (59.3 ± 2.5 vs. 56.0 ± 1.0). For DIEP-SIEV links, XR yielded significantly higher overall counts than 2D images (P = 0.04). Interobserver reliability was moderate for 2D images but improved with XR, particularly among the juniors. The Bland-Altman analysis demonstrated reduced variability and narrower agreement limits with XR, thereby indicating improved observer consistency. In the five hemi-abdomens used for DIEP flap harvest, the mean absolute error relative to the intraoperative reference was significantly lower with XR than with 2D imaging for all surgeons (0.86 ± 0.73 vs. 2.66 ± 1.75, P < 0.0001), and for junior (0.90 ± 0.79 vs. 3.50 ± 1.73, P < 0.0001) and senior surgeons (0.80 ± 0.68 vs. 1.53 ± 0.99, P = 0.022). CONCLUSIONS: XR visualization improved interobserver agreement and reduced experience-related variability in DIEP vascular assessment, with perforator counts aligning more closely with the intraoperative findings. XR may be a useful adjunct to preoperative planning and surgical education; however, further studies are needed to establish its impact on operative performance and patient outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers