Cervical spine motion during tracheal intubation with videolaryngoscopy versus macintosh laryngoscopy in adults undergoing cervical spine surgery: a randomized controlled trial.
Hieu Trung Doan, Thang Toan Nguyen, Anh Thi Hong Nguyen, Du Gia Hoang
Bach Mai Hospital, Center for Anesthesia and Surgical Intensive Care, Hanoi, Vietnam. · Bach Mai Hospital, Center for Anesthesia and Surgical Intensive Care, Hanoi, Vietnam; Hanoi Medical University, Department of Anesthesia and Critical Care, Hanoi, Vietnam. Electronic address: nguyentoanthang@hmu.edu.vn.
Key points
From the paper's conclusion- ClearVue videolaryngoscopy reduced fluoroscopically measured upper cervical and directly measured cumulative C0‒C5 motion compared with Macintosh direct laryngoscopy. These findings should be interpreted as biomechanical surrogate outcomes, not as evidence of neurological protection.
Abstract
BACKGROUND: Excessive cervical spine motion during tracheal intubation may increase neurological risk in individuals with cervical spine pathology. Videolaryngoscopy may reduce cervical motion compared with Macintosh direct laryngoscopy, but any biomechanical reduction should be distinguished from neurological protection. METHODS: Adults scheduled for elective cervical spine surgery were randomized 1:1 to intubation with a ClearVue videolaryngoscope (group V) or a Macintosh laryngoscope (group M) under manual in-line stabilization. Lateral fluoroscopy was acquired immediately before laryngoscopy (G0, neutral position) and at best glottic view (G1). The prespecified primary endpoint was directly measured cumulative C0‒C5 cervical motion. Cervical spine motion (ΔG) was also calculated at C0‒C1, C1‒C2, C2‒C3, C3‒C4 and C4‒C5. ΔG was expressed in degrees (°). RESULTS: Fifty-six patients were randomized and analyzed (28 per group). Mean (SD) ΔG at C0‒C5 was 19.71 (4.75) in group V and 26.32 (8.46) in group M (mean difference [M‒V], 6.61; 95% CI 2.91‒10.31; p < 0.001). At C0‒C1, ΔG was 2.68 (2.53) vs. 4.68 (2.42) (difference = 2.00; 95% CI 0.67‒3.33; p = 0.004). First-attempt success was 89.3% (25/28) vs. 78.6% (22/28) (p = 0.47). Among patients intubated successfully on the first attempt, intubation time was shorter in group V (21.75 ± 3.64s) than group M (31.71 ± 21.25s). CONCLUSION: ClearVue videolaryngoscopy reduced fluoroscopically measured upper cervical and directly measured cumulative C0‒C5 motion compared with Macintosh direct laryngoscopy. These findings should be interpreted as biomechanical surrogate outcomes, not as evidence of neurological protection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Challenging Dogma: Videolaryngoscopy to Limit Cervical Spine Injury?A&A practice · 2026
- GlideRite® rigid stylet vs Flex-it® articulated stylet for intubation with videolaryngoscopy in patients with semi-rigid cervical collar: a randomized trial.Brazilian journal of anesthesiology (Elsevier) · 2026
- The C-MAC video laryngoscope versus fiberoptic bronchoscope for awake intubation under ketofol sedation in cervical spine injury patients who are immobilized with a cervical collar: a prospective randomized controlled trial.Journal of trauma and injury · 2026
- Clinical comparison of midline versus right-sided video laryngoscope insertion for endotracheal intubation in difficult airways: a randomized controlled trial.Anesthesia and pain medicine · 2026
- Comparison of upper limb muscle activity and workload during intubation with the Macintosh direct laryngoscope versus C-MAC® and King Vision® videolaryngoscopes in simulated difficult airway scenarios: a randomized crossover trial.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- A Comparative study on the hemodynamic changes between King Vision Videolaryngoscope and Macintosh direct laryngoscope in orotracheal intubation under general anesthesiaAsian Journal of Medical Sciences · 2026