Biosensors & bioelectronics

Computationally steered toehold engineering accelerates primer exchange reaction for rapid detection of congenital heart disease-associated miRNAs.

Yating Zhang, Chuming Zhang, Ao Sun, Hong Chen, Guangli Ren, Xiangmeng Qu

School of Biomedical Engineering, Shenzhen Campus of Sun Yat-Sen University, Shenzhen, 518017, China. · School of Intelligent Manufacturing (Pen-Tung Sah Institute of Micro-Nano Science and Technology), State Key Laboratory of Vaccines for Infectious Diseases, Xiang An Biomedicine Laboratory, Xiamen University, Xiamen, 361005, China.

Key points

From the paper's conclusion
  • We further evaluated the accelerated PER platform by separately detecting three CHD-associated miRNAs (miR-146a-5p, miR-122-5p, and miR-548am-3p) in clinical serum samples and combining their fluorescence responses for exploratory analysis.

Abstract

Isothermal nucleic acid amplification, including the primer exchange reaction (PER), provides a promising basis for molecular diagnostics with potential for point-of-care testing (POCT). However, its clinical translation is severely bottlenecked by prolonged reaction times (typically >4 h) originating from the intrinsic nucleation barrier during initial target recognition. Here, we propose a synergistic computational-experimental paradigm to accelerate PER kinetics by rationally modulating the target-recognition toehold length. By employing oxDNA coarse-grained molecular dynamics simulations and NUPACK thermodynamic computations, we systematically decode the free-energy landscape of target-probe interactions. Both theoretical modeling and experimental validation consistently reveal that a precisely extended 15-nucleotide (nt) recognition toehold facilitates initial target recognition and promotes subsequent strand displacement, thereby accelerating the initiation of the PER process. Operating via a programmable dGTP-depleted enzymatic cascade, this precision molecular engineering yields a 75% temporal reduction, compressing PER amplification time to a mere 60 min. The toehold-engineered amplification platform achieves an analytical limit of detection of approximately 662 fM, demonstrating its capability for low-concentration target detection. The observed differences in fluorescence responses among the clinical groups suggest the feasibility of applying the platform to CHD-associated circulating miRNA profiling. We further evaluated the accelerated PER platform by separately detecting three CHD-associated miRNAs (miR-146a-5p, miR-122-5p, and miR-548am-3p) in clinical serum samples and combining their fluorescence responses for exploratory analysis. Preliminary differences were observed among the clinically defined groups. This study establishes a thermodynamically steered kinetic acceleration strategy for dynamic DNA reactions, offering a rapid, reliable, and clinically actionable avenue for early disease screening.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Computationally steered toehold engineering accelerates primer exchange reaction for rapid detection of congenital heart disease-associated miRNAs — Science Skim