Effects of cathodic polarization and coating defect size on SRB biofilm-associated corrosion of Q355 steel.
Yueqi Wang, Fang Guan, Xiaofan Zhai, Ding Guo, Ziqi Zhao
State Key Laboratory of Advanced Marine Materials, Laboratory of Marine Environmental Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China; College of Bioengineering, Qilu University of Technology (Shandong Academy of Sciences), 3501 Daxue Road, Changqing District, Jinan 250353, Shandong Province, China. · State Key Laboratory of Advanced Marine Materials, Laboratory of Marine Environmental Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao 266071, China. Electronic address: guanfang@qdio.ac.cn.
Key points
From the paper's conclusion- This study investigates the effect of cathodic polarization and coating defect size on sulfate-reducing bacteria (SRB)-associated corrosion of Q355 steel protected by an epoxy primer/polyurethane topcoat system.
Abstract
This study investigates the effect of cathodic polarization and coating defect size on sulfate-reducing bacteria (SRB)-associated corrosion of Q355 steel protected by an epoxy primer/polyurethane topcoat system. Artificial pinhole defects with diameters of 0.2, 0.5 and 1 mm were introduced on the coating, and the corrosion behavior was evaluated via corrosion morphology observation at defect sites, electrochemical measurements and characterization of microbial adhesion. In the absence of cathodic polarization, larger defects facilitated SRB biofilm formation and intensified localized corrosion. After 14 days of cathodic polarization application, the cathodic polarization at -0.95 VCSE provided the most effective protection for small defects, the bacterial adhesion was inhibited and protective calcareous deposits were formed. For specimens under cathodic protection potentials of -0.85 VCSE and - 0.95 VCSE, no cathodic disbondment was observed after 14 days of polarization. When the polarization period was extended to 60 days, cathodic disbondment propagated radially outward from the central artificial defect on the specimen surface. The cathodic potential of -0.95 VCSE led to more coating damage propagation than those under non-polarized and - 0.85 VCSE conditions, and 0.2 mm initial defects yielded higher area expansion ratios at equal polarization potentials.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Numerical study on cathodic protection effect of deep defects on pipelines with constant loadMaterials Today Communications · 2026
- Microbiologically influenced corrosion behavior of 10CrNi5MoV high-strength steel in marine environments.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Microbiologically assisted stress corrosion cracking of X80 pipeline steel welded joint under cathodic protectionActa Materialia · 2025
- Top‐ and bottom‐of‐the‐line corrosion: Effects of 30 °C bottom liquid and 20 °C steel temperature in CO 2 and H 2 S/N 2 environmentsMaterialwissenschaft und Werkstofftechnik · 2026
- Long-term corrosion evolution of titanium and Ti5Cu alloy in the oral environment driven by Streptococcus mutans.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Improved Corrosion Resistance of Q235 Steel in 3.5 wt% NaCl Solution by N, P Co-Doped Carbon Dots with Efficient Antibacterial and Fluorescent PropertiesLangmuir · 2025