Precise detection of telomerase reverse transcriptase C228T mutation using label-free and magnetically induced self-assembly electrochemical biosensors.
Wentao Li, Min Liu, Zhanyi Qu, Qianqian Deng, Ruijiang Liu, Zhan-Ao Wu
School of Pharmacy, Jiangsu University, Zhenjiang, 212013, PR China. · The People's Hospital of Danyang, Affiliated Danyang Hospital of Nantong University, Zhenjiang, 212300, PR China.
Key points
From the paper's conclusion- Overall, the electrochemical biosensors offer a simple, rapid, and ultrasensitive platform for TERTC228T detection, with promising potential for molecular diagnosis and thyroid cancer risk stratification.
Abstract
Telomerase reverse transcriptase promoter C228T mutations (TERTC228T) are strongly associated with poor outcomes in papillary thyroid cancer, necessitating sensitive detection methods. In this work, a "Signal-off" type of label-free and magnetically induced self-assembly electrochemical biosensors based on α-Fe2O3/Fe3O4@Au magnetic nanocomposites (MNCs) were developed for TERTC228T detection. Thiolated aptamers (Apts) for specific recognition of TERTC228T were immobilized on α-Fe2O3/Fe3O4@Au MNCs via AuS bonds, and bovine serum albumins (BSA) were employed to block non-specific sites and form α-Fe2O3/Fe3O4@Au-Apt/BSA biosensors. TERTC228T specifically hybridized with Apts, forming a rigid dsDNA film on the electrode. Enhanced steric hindrance and electrostatic repulsion suppressed electron transfer of [Fe(CN)6]3-/4-, leading to decreased current signals. The biosensors were evaluated by cyclic voltammetry, electrochemical impedance spectroscopy, and differential pulse voltammetry, the results demonstrated that the biosensors exhibited a wide linear range (102 pM- 106 pM), high sensitivity (LOD of 0.67 pM), and excellent selectivity, along with high reproducibility (RSD = 1.84%) and long-term stability (signal retention above 95% within 10 days), and enabled reliable detection in diluted human serum (recoveries of 98.1%-107.3%). Overall, the electrochemical biosensors offer a simple, rapid, and ultrasensitive platform for TERTC228T detection, with promising potential for molecular diagnosis and thyroid cancer risk stratification.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Highly Catalytic FeS₂ @CoS₂ Core/Shell Nanocubes for Ultrasensitive Electrochemical Assay of Microphthalmia-Associated Transcription Factor via Nucleic Acid Signal Amplification CascadesAnalytical Chemistry · 2025
- An indicator-free electrochemical magnetoresistance nano aptamer-biosensor for the ultra-sensitive determination of B-Raf proto-oncogeneFrontiers in Chemistry · 2026
- A type of magnetically induced self-assembled electrochemical aptamer nanobiosensor for ultrasensitive detection of hypoxia-inducible factor 1α protein.Frontiers in chemistry · 2026
- Ce-doped BiF3@Pt nanocatalyst enhanced CHA-based electrochemical biosensor for sub-femtomolar detection of miRNA-21.Bioelectrochemistry (Amsterdam, Netherlands) · 2026
- Label-Free Peptide Nucleic Acid-Based Electrocatalytic Biosensor Coupled with EXPAR for Ultrasensitive Detection of miR-181b.Biosensors · 2026
- Strong Self-Off Biosensor Based on Proximity-Induced DNA Strand Displacement Triggered Controlled Release for Dual-Mode Sensitive Analysis of Neuron Specific EnolaseAnalytical Chemistry · 2026