Label-Free Peptide Nucleic Acid-Based Electrocatalytic Biosensor Coupled with EXPAR for Ultrasensitive Detection of miR-181b.
Guanxu Chen, Jingwei Zhou, Qianqian Feng, Qixiang Zhao, Chuiju Zhang, Yuxi Fang, Jinyuan Chen, Guangxian Zhong
School of Health, Fujian Medical University, Fuzhou 350108, China. · The Graduate School, Fujian Medical University, Fuzhou 350122, China.
Key points
From the paper's conclusion- Here, we describe a label-free electrocatalytic electrochemical biosensor that pairs a peptide nucleic acid (PNA) capture probe with the exponential amplification reaction (EXPAR).
Abstract
Osteosarcoma (OS) is the most common primary malignant bone tumor in adolescents. Diagnosis usually comes late because micrometastases are hard to see on imaging or in biopsy specimens. Exosomal microRNAs survive well in body fluids and have therefore become popular markers for liquid biopsy. miR-181b is abnormally expressed in OS, yet it occurs at low levels in body fluids and differs from miR-181a, miR-181c, and miR-181d by only a few bases. Measuring it demands both high sensitivity and high specificity. Here, we describe a label-free electrocatalytic electrochemical biosensor that pairs a peptide nucleic acid (PNA) capture probe with the exponential amplification reaction (EXPAR). A 3'-thiolated PNA probe was attached to a gold electrode by rapid freezing-assisted Au-S bonding. EXPAR converted the target into single-stranded DNA, which bound PNA and a signal probe to form a sandwich. PNA carries a neutral backbone, whereas DNA is negatively charged, so [Ru(NH3)6]3+ was adsorbed onto the sandwich by electrostatic attraction. [Fe(CN)6]3- then re-oxidized the reduced Ru complex in a catalytic cycle, and square wave voltammetry recorded the current. Under optimized conditions, the sensor responded linearly to miR-181b from 1 fM to 1 nM, with an experimental detection limit of 1 fM. It separated miR-181b from miR-181a, miR-181c, and miR-181d, and the inter-day RSD over 3 consecutive days was 4.34% (n = 9; three electrodes per day). After 6 days of storage in PBS at 4 °C, the electrodes still delivered 83.8% of their initial response. All measurements used synthetic miR-181b. Clinical validation and long-term shelf-life stability have not yet been established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Flexible microneedle array with AuNPs/MXene for visualized electrochemical monitoring of osteosarcoma miR-181b.Frontiers in bioengineering and biotechnology · 2026
- Exonuclease III-Proofread high-fidelity primer exchange reaction enables ultrasensitive analysis of prostate cancer MicroRNA.Biosensors & bioelectronics · 2026
- Aldehyde-Hydrazide Crosslinking for Polysaccharide-Amplified Electrochemical Detection of Nucleic AcidsAnalytical Chemistry · 2026
- In Vivo Molecular Imaging of OGG1 Activity Using a Cyclic Cleavage-Amplified DNA Nanodevice.Analytical chemistry · 2026
- Peptide Nucleic Acid Origami for Cancer Diagnostics.Biosensors · 2026
- A Novel Dual Signal Amplification Strategy Integrating APE1-Assisted DNA Walker with Rolling Circle Amplification for Highly Sensitive, Label-Free Exosomal microRNA AnalysisAnalytical Chemistry · 2026