Annals of vascular surgery

Systematic Review of Clinical Outcomes With the E-tegra™ Stent Graft System for Endovascular Aneurysm Repair: Endoleaks, Limb Patency, Reinterventions, Aneurysm Sac Behaviour, and Mid-Term Follow-Up.

Rafael de Athayde Soares

Instituto de Assistência Médica ao, Servidor Público Estadual de São Paulo (IAMSPE), São Paulo, Brazil, Division of Vascular and Endovascular Surgery, Hospital do Servidor Público Estadual de São Paulo, Brazil. Electronic address: drrafaelsoaresvasc@gmail.com.

Review

Key points

From the paper's conclusion
  • Early and mid-term evidence for the E-tegra stent graft demonstrates high procedural success and acceptable clinical outcomes with competitive mid-term complication and reintervention rates. However, the current literature is strictly limited to single-arm observational data with short-to-medium horizons (18-24 months). Long-term durability and structural performance relative to well-established companion platforms remain unestablished, highlighting the critical need for continued prospective surveillance and comparative, long-term multicenter trials.

Abstract

OBJECTIVE: To systematically synthesize the published clinical evidence regarding endovascular aneurysm repair (EVAR) using the E-tegra™ stent graft system, evaluating technical success, endoleaks, limb patency, reinterventions, aneurysm sac behavior, and mid-term follow-up outcomes. METHODS: Conducted according to the PRISMA 2020 framework, systematic searches were performed across PubMed/MEDLINE, Embase, Scopus, and the Cochrane databases. Observational studies and registry reports reporting clinical outcomes of adults undergoing EVAR with the E-tegra system were included. Because of cohort overlap and heterogeneous endpoint definitions, data were synthesized narratively and descriptively without formal quantitative pooling. RESULTS: Three eligible publications were identified, representing 209 unique patients across two underlying cohorts: the multicenter TIGRE registry (147 patients) and an independent single-center series (62 patients). Primary technical success was high, reaching 99.3% in the registry and 100% in the single-center cohort, with zero perioperative mortality across both. At mid-term follow-up (ranging from 18 months to 2 years), type II endoleak and iliac limb occlusion emerged as the primary complications. The TIGRE update reported 16 total complications (10.88%), including 8 type II endoleaks and 6 iliac limb occlusions, with a 2-year reintervention rate of 4.76%. In the single-center series, 1 type IIIa endoleak (1.6%) and 3 clinically significant type II endoleaks requiring embolization were observed. Favorable mid-term sac behavior was noted in the registry, with 72.11% of patients demonstrating >10-mm aneurysm sac shrinkage. Predefined anatomical hostility did not demonstrate a statistically significant association with adverse outcomes or reinterventions in the registry data. CONCLUSIONS: Early and mid-term evidence for the E-tegra stent graft demonstrates high procedural success and acceptable clinical outcomes with competitive mid-term complication and reintervention rates. However, the current literature is strictly limited to single-arm observational data with short-to-medium horizons (18-24 months). Long-term durability and structural performance relative to well-established companion platforms remain unestablished, highlighting the critical need for continued prospective surveillance and comparative, long-term multicenter trials.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers