A STANDARDIZED 50-MM ANALYTICAL MODEL FOR REPRODUCIBLE ANEURYSM VOLUMETRY AFTER EVAR.
Ma Lourdes Del Río-Solá, Joan Roedan-Oliver, Manuel Diez-Martínez, Alfredo Redondo-Diéguez
Department of Vascular Surgery; University Hospital, Valladolid (Spain). Department of Surgery, Ophthalmology, Otorhinolaryngology, Physiotherapy; University of Valladolid. Department of Health Siciences; Miguel de Cervantes European University, Valladolid, Spain. Electronic address: marialourdes.rio@uva.es. · Department of Vascular Surgery. University Hospital, Valladolid, Spain.
Key points
From the paper's conclusion- Volmax50 provides more reproducible and sensitive volumetric assessment than conventional volumetry for AAA surveillance after EVAR. By standardizing the analytical region and reducing observer-related variability, it improves the detection of sac volume changes and may represent a useful adjunct for routine postoperative monitoring.
Abstract
BACKGROUND: Conventional volumetric assessment after endovascular aneurysm repair (EVAR) is limited by variability in anatomical landmark selection and inconsistent measurement regions, which may affect longitudinal reproducibility. This study evaluated the reproducibility and sensitivity of Volmax50, a standardized volumetric framework based on a patient-specific 50-mm analytical segment automatically identified within the region of maximal aneurysm dilatation, compared with conventional full-length volumetry. METHODS: A prospective single-center study included 98 patients undergoing endovascular aneurysm repair (EVAR). Sac and thrombus volumes were obtained using semi-automated segmentation and analyzed with two approaches: traditional full-length volumetry and Volmax50, which evaluates a fixed 50-mm segment centered on maximal sac dilatation. Measurements were performed at baseline, 6, and 12 months. Agreement, intra- and interobserver reproducibility, and sensitivity for detecting sac enlargement ≥5 mL were assessed. RESULTS: Baseline sac and thrombus volumes were comparable between methods. During follow-up, Volmax50 yielded slightly larger sac volumes (T6: 110 vs 105 mL, p=0.041; T12: 114 vs 107 mL, p=0.019) and thrombus volumes (T12: 52 vs 50 mL, p=0.044). Reproducibility was superior with Volmax50 (ICC 0.93, 95% CI 0.90-0.96) compared with the traditional method (ICC 0.82, 95% CI 0.76-0.87), with lower intra- and interobserver variability (2.8% and 3.4% vs 6.5% and 7.9%). Bland-Altman analyses confirmed smaller bias and narrower limits of agreement. Sensitivity for detecting sac enlargement ≥5 mL was significantly higher with Volmax50 (92% vs 68%, p<0.001). CONCLUSIONS: Volmax50 provides more reproducible and sensitive volumetric assessment than conventional volumetry for AAA surveillance after EVAR. By standardizing the analytical region and reducing observer-related variability, it improves the detection of sac volume changes and may represent a useful adjunct for routine postoperative monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Volumetric Analysis versus Diameter Measurement for Early Detection of Post-EVAR Sac Progression.Vascular and endovascular surgery · 2026
- Decoding the Aneurysm Thrombus: Radiomic Signatures of Sac Shrinkage After EVAR.Annals of vascular surgery · 2026
- Fully automated assessment of post-TEVAR follow-up CT scan using Deep Learning-Based Segmentation.Annals of vascular surgery · 2026
- Multi-centre Validation of Automated Outer-to-Outer Wall Segmentation of Infrarenal Abdominal Aortic Aneurysms Using a nnU-Net Based Model.Journal of imaging informatics in medicine · 2026
- Evaluation of Total Patent Branch Vessel Ostial Area at Preoperative CT Angiography for Predicting Type II Endoleak after Endovascular Aneurysm Repair.Radiology · 2026
- A Systematic Review and Meta-Analysis on 30-Day Readmission Rates After Endovascular Abdominal Aortic Aneurysm Repair and Open Repair.Annali italiani di chirurgia · 2026