Multi-centre Validation of Automated Outer-to-Outer Wall Segmentation of Infrarenal Abdominal Aortic Aneurysms Using a nnU-Net Based Model.
Cas H F Hendricks, Willemina A van Veldhuizen, Amin Ranem, Bram Fioole, Rogier H J Kropman, Jelmer M Wolterink, Jean-Paul P M de Vries
Division of Vascular Surgery, Department of Surgery, University Medical Centre Groningen, Hanzeplein 1, Groningen, 9700 RB, the Netherlands. c.h.f.hendricks@umcg.nl. · Division of Vascular Surgery, Department of Surgery, University Medical Centre Groningen, Hanzeplein 1, Groningen, 9700 RB, the Netherlands.
Key points
From the paper's conclusion- This study aimed to validate a pre-trained open-source nnU-Net-based model for fully automated outer-to-outer wall segmentation of the abdominal aorta in AAA patients.
Abstract
Accurate outer-to-outer wall aortic segmentation is essential for abdominal aortic aneurysm (AAA) assessment and endovascular aneurysm repair (EVAR) planning, yet manual segmentation is time-consuming and impractical for routine use. This study aimed to validate a pre-trained open-source nnU-Net-based model for fully automated outer-to-outer wall segmentation of the abdominal aorta in AAA patients. In this retrospective multicentre observational validation study, 75 consecutive AAA patients (25 per centre) from three Dutch hospitals were included. Manual segmentations of pre-EVAR CTA scans were performed. A second observer independently segmented 30 cases to assess interobserver variability. Manual and automatic segmentations were compared using the Dice similarity coefficient (DSC), Jaccard index, maximum and 95th percentile Hausdorff distances (HD max, HD95), mean surface distance, and absolute and relative volume difference. Agreement was assessed for the full abdominal aorta and the infrarenal neck separately. Automatic segmentation achieved excellent agreement with manual segmentations, with a median DSC of 0.97 (IQR 0.96-0.97) and median HD95 of 5.5 (IQR 3.8-7.6) mm. The mean volume bias was 2.06 ml. Performance was comparable to interobserver variability between manual segmentations (median DSC 0.96 [IQR 0.95-0.97]). For the infrarenal neck, a median DSC of 0.95 (IQR 0.93-0.96) was achieved. Automatic segmentation required less than one minute per scan on a dedicated GPU, compared to 45-60 minutes for manual segmentation. Automated outer-to-outer wall aortic segmentation using a pre-trained nnU-Net-based model achieves excellent agreement with manual segmentations, comparable to interobserver variability, across a consecutive multicentre dataset. This approach may support more reproducible and efficient AAA analysis in clinical and research settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A novel morphological assessment approach for abdominal aortic aneurysms: automated segmentation and measurement using a semi-supervised deep learning algorithm.Frontiers in cardiovascular medicine · 2026
- TotalSegmentator Aorta Report: Automated Aortic Diameter Measurement at 11 Standardized Landmarks on CT ImagesarXiv · 2026
- Artificial Intelligence in 3D Aortic CTA Segmentation for Abdominal Aortic Aneurysm Management: A Narrative Review.Journal of imaging · 2026
- Artificial intelligence–based fully automated multi-class segmentation of aortic dissection in computed tomography imagesEuropean Heart Journal · 2026
- Automated CTA-Based Assessment of Aortic Remodeling Through Volumetric Biomarkers in Type B Aortic DissectionmedRxiv · 2026
- Development and validation of an AI decision support system for automated 17-zone mapping and subtype diagnosis of acute aortic syndrome on CTAEuropean Heart Journal · 2026