Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Development of a real-time CMOS gamma radiation dosimeter sensor.

T R Abdulhamid, R A Fouad, M M Kassab, A Abdel-Latif

Mathematics and Physics Department, Faculty of Engineering, Fayoum University, Fayoum, 63511, Egypt. Electronic address: tra11@fayoum.edu.eg. · Electrical Engineering Department, Faculty of Engineering, Fayoum University, Fayoum, 63514, Egypt.

Key points

From the paper's conclusion
  • This work presents a real-time gamma-ray dosimeter designed and simulated in a 130 nm CMOS technology.

Abstract

Radiation dosimetry is essential in applications such as medical irradiation, space electronics, and nuclear technology. This work presents a real-time gamma-ray dosimeter designed and simulated in a 130 nm CMOS technology. The proposed system employs a floating-gate MOSFET (FGMOSFET) sensing element integrated with a current-to-voltage converter and a 5-bit successive approximation register (SAR) analog-to-digital converter (ADC). Simulation results show operation from a single 1.2 V supply, a dose measurement range of 0-50 Gy, and a nominal dose resolution of 1.56 Gy. The system consumes 1.7-3.8 mW and achieves a conversion time of 5 ms. These results indicate the potential of the proposed architecture for dose-verification applications, including blood irradiation. Layout-level evaluation and experimental validation are left for future work.

Read the paper