Monte Carlo simulations of a custom-made neutron probe based on the SI-19N proportional 3He counter.
Pavol Blahušiak, Branislav Vrban, Petra Konečná, Jakub Lüley, Štefan Čerba
Slovak Institute of Metrology (SMU), Karloveská 63, 841 04, Bratislava, Slovakia. Electronic address: blahusiak@smu.gov.sk. · Institute of Nuclear and Physical Engineering (INPE), FEI STU, Ilkovičova 3, 841 04, Bratislava, Slovakia.
Key points
From the paper's conclusion- To support the design process, Monte Carlo simulations of the neutron fluence response were performed.
Abstract
Proportional 3He counters of the SI-19N type are widely used and readily available, making them suitable candidates for neutron detection systems. When combined with an appropriate electronic readout and a well-optimized high-density polyethylene (HDPE) moderator, these detectors can serve as highly effective neutron probes with a broad range of applications. The design presented here is tailored to meet the operational requirements of the Centre of Nuclear Technology and Applications (CeNTA), specifically for characterizing neutron fields produced by a DD neutron generator. The installed neutron generator is an open system denoted as Adelphi DD-108. The probe is intended for use both as an absolute neutron counter and as a rate meter, while also maintaining adequate sensitivity to neutron fields from common radioisotopic sources such as 252Cf and 241Am-Be. To support the design process, Monte Carlo simulations of the neutron fluence response were performed. Response functions were calculated using the MCNP6.2 radiation transport code for multiple moderator-thickness configurations. The simulations employed the well-validated ENDF/B-VII.1 nuclear data library as well as the latest ENDF/B-VIII.1. Data obtained from the simulations were compared with experimental data from the metrological testing of the probe. The aim of this study is to provide the basis for determining the optimal probe configuration and the metrological characterization of an inexpensive counter for versatile neutron field measurements at CeNTA. Finally, the calibration of the newly constructed detector was performed and is documented in this paper.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Experimental validation of a newly developed neutron ambient dose H* detector in an accelerator-based BNCT fieldJapanese Journal of Applied Physics · 2026
- Monte Carlo characterization study of a TLD-600/TLD-700 neutron personal dosimeter exposed to a 252Cf source on an ISO water phantom at LPN-CIEMAT.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- A comprehensive microdosimetric study of neutron capture enhanced proton therapy: physical dose to RBE-based evaluation.Journal of radiation research · 2026
- Benchmarking Monte Carlo codes for the modelling of low-energy neutron production target reactionsComputer Physics Communications · 2025
- Experimental validation of MCNP simulation model for Cu-64 production by fast neutron irradiation.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Characterization of the fast neutron response of liquid scintillator detectors at NFSarXiv · 2026