Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Monte Carlo simulations of a custom-made neutron probe based on the SI-19N proportional 3He counter.

Pavol Blahušiak, Branislav Vrban, Petra Konečná, Jakub Lüley, Štefan Čerba

Slovak Institute of Metrology (SMU), Karloveská 63, 841 04, Bratislava, Slovakia. Electronic address: blahusiak@smu.gov.sk. · Institute of Nuclear and Physical Engineering (INPE), FEI STU, Ilkovičova 3, 841 04, Bratislava, Slovakia.

Computational

Key points

From the paper's conclusion
  • To support the design process, Monte Carlo simulations of the neutron fluence response were performed.

Abstract

Proportional 3He counters of the SI-19N type are widely used and readily available, making them suitable candidates for neutron detection systems. When combined with an appropriate electronic readout and a well-optimized high-density polyethylene (HDPE) moderator, these detectors can serve as highly effective neutron probes with a broad range of applications. The design presented here is tailored to meet the operational requirements of the Centre of Nuclear Technology and Applications (CeNTA), specifically for characterizing neutron fields produced by a DD neutron generator. The installed neutron generator is an open system denoted as Adelphi DD-108. The probe is intended for use both as an absolute neutron counter and as a rate meter, while also maintaining adequate sensitivity to neutron fields from common radioisotopic sources such as 252Cf and 241Am-Be. To support the design process, Monte Carlo simulations of the neutron fluence response were performed. Response functions were calculated using the MCNP6.2 radiation transport code for multiple moderator-thickness configurations. The simulations employed the well-validated ENDF/B-VII.1 nuclear data library as well as the latest ENDF/B-VIII.1. Data obtained from the simulations were compared with experimental data from the metrological testing of the probe. The aim of this study is to provide the basis for determining the optimal probe configuration and the metrological characterization of an inexpensive counter for versatile neutron field measurements at CeNTA. Finally, the calibration of the newly constructed detector was performed and is documented in this paper.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers