Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Thermoluminescence and trapping-state complexity of Pr3+-activated K3Gd(BO2)6: dosimetric response and cross-method kinetic analysis.

M Sharahili, E A Cin, K Bulcar, U H Kaynar, N Can

Jazan University, College of Science, Department of Physical Sciences, Physics Division, P.O. Box 114, 45142, Jazan, Kingdom of Saudi Arabia. · Bakırçay University, Graduate School of Natural and Applied Sciences, Menemen, İzmir, Türkiye.

Key points

From the paper's conclusion
  • We report the first known thermoluminescence and dosimetric study of Pr3+-activated K3Gd(BO2)6.

Abstract

We report the first known thermoluminescence and dosimetric study of Pr3+-activated K3Gd(BO2)6. Undoped and nominally Pr3+-doped phosphors were prepared by microwave-assisted sol-gel combustion and evaluated under 90Sr/90Y beta irradiation. X-ray diffraction confirmed the dominant trigonal R32 K3GdB6O12-type phase in undoped and 2 mol% samples. Across the 0-7 mol% series, the 2 mol% sample gave the highest response, with peak height and 30-400 °C area 3.13 and 1.95 times those of the host. Preheating at 200 °C for 9 s suppressed the 115 °C contribution while retaining the 257 °C peak (99.7% unadjusted; 100.5% dose-adjusted). Including all 20 dose levels over 1.4-495.5 Gy, area and peak height gave sublinear power-law exponents of 0.933 ± 0.008 and 0.948 ± 0.004 (regression standard errors); low-dose repeatability remains unverified. Three ten-cycle sets remained within ±5%. Variable-heating-rate analysis yielded effective E = 1.534 ± 0.044 eV and s = 4.19 × 1013 s-1; full lag correction increased these to 2.200 ± 0.021 eV and 3.33 × 1020 s-1. Tm-Tstop analysis revealed a 255.1-258.3 °C plateau bounded by discontinuities and rising branches. Initial-rise estimates (n = 51) spanned 0.648-1.757 eV, window sensitivity reaching 0.410 eV. General-order deconvolution resolved dominant contributions at 255.97 and 257.07 °C with energies of 1.390 and 1.332 eV (FOM 0.594% and 1.252%) despite serially correlated residuals. The four kinetic methods indicate a dominant trapping domain near 256 °C with a common energy scale of 1.3-1.5 eV, while residual structure and parameter sensitivity preclude equating fitted components with unique traps.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers