Key points

From the paper's conclusion
  • CaSO4-based phosphors codoped with thulium (Tm) and manganese (Mn) were synthesized by the slow evaporation method and evaluated for thermoluminescent (TL) and optically stimulated luminescent (OSL) beta dosimetry.

Abstract

CaSO4-based phosphors codoped with thulium (Tm) and manganese (Mn) were synthesized by the slow evaporation method and evaluated for thermoluminescent (TL) and optically stimulated luminescent (OSL) beta dosimetry. Two thulium precursors, metallic Tm and Tm2O3, were investigated, while Mn was introduced as Mn(NO3)2·4H2O, with both dopants at a nominal concentration of 0.1 mol%. X-ray diffraction confirmed the formation of the orthorhombic CaSO4 phase, with no detectable secondary crystalline phases, and energy-dispersive spectroscopy (EDS) validated the presence and spatial distribution of Ca, S, O, Tm, and Mn. The phosphors were incorporated into Teflon-based pellets and irradiated with a90Sr/90Y beta source. TL glow curves measured with Hoya U-340 and Schott BG-39 filters showed broad emission components centered near 155 °C and 270 °C, indicating traps with different thermal stabilities. OSL measurements revealed slowly decaying signals that remained measurable throughout the 40 s stimulation period. The samples showed good reproducibility, with coefficients of variation below 10.2%, and linear dose-response relationship from 0.16 Gy to 100 Gy for TL and to 100 Gy for OSL. After 30 days of storage, the TL signal retained a significant fraction of its initial intensity, whereas the OSL signal exhibited fading above 85%. The lower detection limits were determined for both TL and OSL measurements. Among the investigated compositions, CaSO4:Tm,Mn prepared from metallic thulium showed the best overall performance, highlighting this codoping route as a promising strategy for developing CaSO4-based materials for TL beta radiation dosimetry.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers