Ethanol-Enhanced Etch rate in alpha irradiated CR-39 detectors.
Jalaluddin Shah, Rosaline Mishra, Arshad Khan, B K Sapra
Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400094, India. · Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400094, India; Homi Bhabha National Institute, Anushaktinagar, Mumbai, 400094, India. Electronic address: rosaline@barc.gov.in.
Key points
From the paper's conclusion- This study aims to venture into faster etching solutions of CR-39 detectors, so as to facilitate their use in routine measurements.
Abstract
CR-39 solid state nuclear track detectors (SSNTDs) are extensively used for alpha particle detection and neutron dosimetry. However, their relatively long chemical etching time in conventional NaOH solutions limits their efficiency in routine applications. This study aims to venture into faster etching solutions of CR-39 detectors, so as to facilitate their use in routine measurements. Unexposed and alpha-particle-exposed CR-39 detectors were etched in 6.25 M NaOH containing different concentrations of ethanol (5% and 7%). Effect of ethanol addition in NaOH etchant resulted in increased bulk etch rate and reduced track development time. However ethanol addition also enhanced a relatively quicker track overlapping time. Alpha exposed CR-39 etching was thus standardised with the track-density stability zone obtained using ethanol added NaOH etchants, for quick etching.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- An algorithm for determining etch sequences for CR-39.The Review of scientific instruments · 2026
- A novel angle-independent neutron detector based on CR-39.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Applying plasma as an etching technique for CN-85 SSNTDs: Comparison study.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026
- Implications and influences of laser polarization states on alpha particle lengths in CR-39 detectorScientific Reports · 2026
- Evaluation of the high-performance TechnoTrak CR-39 for detection of 1-9 MeV fusion protons.The Review of scientific instruments · 2026
- Comparative evaluation of LR115 and CR39 based Radon, Thoron and their progeny dosimeters.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026