Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

Single-peak thermoluminescence models with temperature-correlated activation energy: Linear and nonlinear cases.

Moschoula Longou, George Kitis

Aristotle University of Thessaloniki, Physics Department, Nuclear Physics and Elementary Particles Physics Section, 54124 Thessaloniki, Greece. · Aristotle University of Thessaloniki, Physics Department, Nuclear Physics and Elementary Particles Physics Section, 54124 Thessaloniki, Greece. Electronic address: gkitis@auth.gr.

Key points

From the paper's conclusion
  • On the other hand, conventional peak-shape, variable-heating-rate, and initial-rise methods fail to evaluate the activation energy of TCAE TL peaks and therefore require reappraisal.

Abstract

A large proportion of the glow curves obtained from natural and synthetic thermoluminescent (TL) materials cannot be analyzed using TL peak models based on a single activation-energy value. In the present work, TL peak models are derived on the basis of a temperature-correlated activation energy (TCAE). Analytical expressions for the corresponding TL peaks, together with their conditions for the maximum, are derived. The suitability of the new analytical expressions as fitting functions in minimization programs is successfully demonstrated by accurately recovering all the parameters required to construct the TCAE line. On the other hand, conventional peak-shape, variable-heating-rate, and initial-rise methods fail to evaluate the activation energy of TCAE TL peaks and therefore require reappraisal.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.