Real-Time Ultrasound-Assisted Laryngeal Electromyography Using an In-Plane Trajectory View: A Prospective Feasibility Study.
Yong Jae Na, Don-Kyu Kim, Sung Joon Park, Yookyung Lee
Department of Physical and Rehabilitation Medicine, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong-si, South Korea. · Department of Otorhinolaryngology-Head and Neck Surgery, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong-si, South Korea.
Key points
From the paper's conclusion- A real-time, in-plane ultrasound-assisted LEMG protocol using a single dedicated trajectory view was feasible and showed a favorable short-term safety profile in this single-arm cohort, performed using commodity ultrasound equipment without electromagnetic tracking. In elderly patients with frequent thyroid cartilage calcification, ultrasound primarily provided trajectory guidance and vascular avoidance; the EMG signal remained the targeting reference. A comparative study against conventional landmark-based LEMG is warranted to establish its additive value.
Abstract
OBJECTIVE: To assess the feasibility, safety, and procedural performance of a real-time ultrasound-assisted laryngeal electromyography (LEMG) protocol that uses a single dedicated in-plane trajectory view for needle guidance, without electromagnetic tracking equipment. DESIGN: Prospective single-arm feasibility study performed by two physicians using an identical standardized technique. SETTING: Single-center university hospital, department of rehabilitation medicine. PARTICIPANTS: Sixteen consecutive adult patients (N=16; 14 men, 2 women; mean age 69.5±10.9 years) referred for LEMG for suspected neuromuscular laryngeal dysfunction. INTERVENTIONS: Following anatomic survey with three orientation views, a single in-plane lateral oblique trajectory was used to sample thyroarytenoid (TA) and cricothyroid (CT) muscles. MAIN OUTCOME MEASURES: (i) Electromyography-confirmed muscle sampling success; (ii) complete real-time needle visualization; (iii) per-structure ultrasound visualization rates; and (iv) procedure-related adverse events. RESULTS: Forty-four muscles (31 TA, 13 CT) were sampled. EMG-confirmed sampling was achieved in 100% (44/44). Complete real-time needle visualization was achieved in 4/31 TA muscles (12.9%) and 13/13 CT muscles (100%); thyroid cartilage calcification (87.5%) was the principal limiting factor for TA. TA and CT muscles were visualized in 100%; arytenoid and vocal cords in 30/32 (93.8%). Transient cough occurred in 3/44 muscle examinations (6.8%); none required termination. No bleeding, hematoma, or infection occurred. CONCLUSIONS: A real-time, in-plane ultrasound-assisted LEMG protocol using a single dedicated trajectory view was feasible and showed a favorable short-term safety profile in this single-arm cohort, performed using commodity ultrasound equipment without electromagnetic tracking. In elderly patients with frequent thyroid cartilage calcification, ultrasound primarily provided trajectory guidance and vascular avoidance; the EMG signal remained the targeting reference. A comparative study against conventional landmark-based LEMG is warranted to establish its additive value.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of upper limb muscle activity and workload during intubation with the Macintosh direct laryngoscope versus C-MAC® and King Vision® videolaryngoscopes in simulated difficult airway scenarios: a randomized crossover trial.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- Thyroid-cartilage and anterior-laryngeal electrodes provide higher and more frequently adequate electromyographic signals in intraoperative neuromonitoring during thyroid surgery: a systematic review and meta-analysis.Gland surgery · 2026
- Can laryngeal ultrasound detect laryngeal movements during mechanically assisted cough?ERJ open research · 2026
- A pilot feasibility study of awake laryngeal ultrasonography in children.European annals of otorhinolaryngology, head and neck diseases · 2026
- Electromyography of the stapedius muscle via a retrofacial approach and electrically evoked stapedius reflex during cochlear implant surgery: a prospective bicentric studyScientific Reports · 2026
- Ultrasound-guided hyomental distance versus weight-based method for ProSeal LMA™ size selection: A randomised controlled study.Indian journal of anaesthesia · 2026