Bailout rotational atherectomy rather than repeat balloon inflation after balloon rupture with extensive dissection and Ellis type II perforation in an undilatable calcified lesion.
K Ouerghi
Service de cardiologie interventionnelle, centre hospitalier de Laval, 33, rue du Haut-Rocher, 53000 Laval, France. Electronic address: ouerghi_kais@hotmail.fr.
Key points
From the paper's conclusion- During predilatation of the distal lesion, a 3.0×30mm semi-compliant balloon ruptured at 16 atm on a calcified nodule, causing an extensive dissection with intramyocardial contrast staining (Ellis type II perforation) and transient flow impairment, with ST-segment elevation, hypotension and acute pulmonary edema.
Abstract
A 91-year-old woman, autonomous and in excellent general condition, on apixaban for paroxysmal atrial fibrillation, was referred for disabling angina. Angiography showed two tight, heavily calcified stenoses of the mid and distal right coronary artery. During predilatation of the distal lesion, a 3.0×30mm semi-compliant balloon ruptured at 16 atm on a calcified nodule, causing an extensive dissection with intramyocardial contrast staining (Ellis type II perforation) and transient flow impairment, with ST-segment elevation, hypotension and acute pulmonary edema. Flow normalized spontaneously, but the lesion remained undilatable. Any new balloon inflation would have loaded the same nodule, with a risk of a second balloon rupture and of Ellis type III perforation, in a patient receiving apixaban, heparin, aspirin and clopidogrel. After recovery of TIMI 3 flow, hemodynamic stabilization and diuretic therapy, the guidewire, which had remained in the true lumen, was exchanged through a 135-cm Caravel microcatheter for a RotaWire Floppy, and bailout rotational atherectomy was performed with a 1.5-mm burr. An undersized 2.5-mm balloon then expanded without indentation, and two drug-eluting stents were implanted without extension of the dissection. At 24 months, the patient remained asymptomatic, without bleeding or thrombotic events. The absence of intravascular imaging is the main limitation of this case: upfront IVUS or OCT assessment of the calcium could have led to planned plaque modification and avoided the complication.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bailout Retrieval of a Ruptured Entrapped Coronary Balloon Using the Reinflation-Deflation Technique (Nantapon-Wittawat Technique).Cureus · 2026
- When an 8-mm Coronary Artery Has No Appropriate Stent: Bailout PCI and Dual-Balloon Optimization in Giant Right Coronary Artery Ectasia.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Inoperable Retroatrial Hematoma Causing Shock After PCI: A Life-Saving Epicardial Bailout.JACC. Case reports · 2026
- Vascular response and silent micro-embolization after rotational atherectomy and drug-coated balloon angioplasty: insights from micro-computed tomography and histologyEuropean Heart Journal - Cardiovascular Imaging · 2026
- Intravascular Lithotripsy Balloon Entrapped in Right Coronary Artery Requiring Surgical Bailout.JACC. Case reports · 2026
- ROBITAL Atherectomy via 5-F Guide for Calcified Left Main Disease With Cardiogenic Shock.JACC. Case reports · 2026