Soleiman Aria, Su Hnin Hlaing, Darren L Walters, Rustem Dautov
BACKGROUND: Sequential ROtational and orBITAL (ROBITAL) atherectomy combines sequential rotational and orbital atherectomy to manage complex coronary calcium. We report its feasibility using a 5-F guiding catheter in a patient with critical left main (LM) disease when larger guides could not achieve stable engagement.
CASE SUMMARY: An 83-year-old woman presented with cardiogenic shock, pulmonary edema, and severe calcified ostial/distal LM disease. After intra-aortic balloon pump insertion, only a 5-F JL 3.5 guide achieved coaxial engagement. ROBITAL atherectomy allowed adequate calcium modification, allowing intravascular ultrasound-guided percutaneous coronary intervention. She recovered fully and remained well 3 years later.
DISCUSSION: Limited literature supports 5-F calcium modification strategies. This case demonstrates ROBITAL atherectomy via a 5-F guide for unstable LM disease when larger guides failed to engage the LM.