American journal of ophthalmology

Constructing an Objective Defocus Curve from Pyramidal Wavefront Aberrometry: Mapping Objective-to-Subjective Through-Focus Response.

Andrea Russo, Francesco Versaci, Vito Romano, Kieren Darcy, Valerio Bo, Ottavia Filini, Stephen Taylor, Alessandro Boldini,

Centro Oculistico Bresciano, Brescia, Italy. Electronic address: dott.andrea.russo@gmail.com. · CSO (Costruzione Strumenti Oftalmici), Florence, Italy.

Observational · n=98

Key points

From the paper's conclusion
  • An objective defocus curve from one pyramidal wavefront acquisition estimated the subjective through-focus response with small bias and limits of agreement of about ±0.2 logMAR in a test set and an independent cohort of refractive IOLs; individual precision, diffractive designs, and pupil-specific curves need further work.

Abstract

PURPOSE: To construct an objective defocus curve from pyramidal wavefront aberrometry and map it onto the subjective through-focus response. DESIGN: Prospective multicenter case series with external validation. SUBJECTS, PARTICIPANTS, AND/OR CONTROLS: 98 eyes of 63 patients implanted with the RayOne Galaxy spiral refractive intraocular lens (IOL) at three centers (Italy, UK); 81 eyes with a wavefront pupil ≥ 4 mm were split by patient into training (56) and test (25) sets; 19 eyes with other refractive extended-depth-of-focus IOLs from a fourth center formed an external cohort. METHODS, INTERVENTION, OR TESTING: Pyramidal aberrometry (Osiris) with numerically introduced defocus from +1.00 to -4.00 diopters (D); the second-moment radius of the geometrical point spread function was mapped to acuity by a rational function and compared with monocular ETDRS defocus curves. MAIN OUTCOME MEASURES: Root-mean-square error (RMSE), bias, and 95% limits of agreement (LoA) between mapped objective and subjective acuity; objective versus subjective depth of field (DOFi). RESULTS: Internal test set: RMSE 0.095 logMAR (95% CI, 0.078-0.110), bias 0.016 logMAR (LoA, -0.168 to +0.201); external cohort: RMSE 0.092 logMAR (0.079-0.103), bias -0.021 logMAR (LoA, -0.197 to +0.155). Objective minus subjective DOFi at 0.20 logMAR was -0.10 D (LoA, -1.44 to +1.25 D) and -0.15 D (LoA, -0.98 to +0.69 D). Cohort-mean subjective DOFi was 2.43 D (Full-DOFi, continuous); corrected distance acuity was 20/20 or better in 88.8%. CONCLUSIONS: An objective defocus curve from one pyramidal wavefront acquisition estimated the subjective through-focus response with small bias and limits of agreement of about ±0.2 logMAR in a test set and an independent cohort of refractive IOLs; individual precision, diffractive designs, and pupil-specific curves need further work.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers