Low-Dose PCCT-Based Liver Volume Perfusion CT with Phase-Specific Reconstruction Optimization for Morphologic.
Yong Chen, Weiping Ma, Bo Ma, Xiaobin Ma, Lu Chen, Yongwei Liu, Aijun Wang, Ping Chen,
Department of Radiology, First Clinical Medical College, General Hospital of Ningxia Medical University, Yinchuan 750004, China (Y.C., W.M., B.M., X.M., A.W, Z.W.). · Siemens Healthineers Ltd. Xi'an Branch, Xi'an 710000, China (L.C.).
Key points
From the paper's conclusion- PCCT-based liver VPCT one-stop imaging reduces radiation exposure while providing diagnostically acceptable morphologic images. The optimal reconstruction of noncontrast and contrast-enhanced images varies by imaging phase, supporting a phase-specific image optimization strategy for liver morphologic assessment.
Abstract
RATIONALE AND OBJECTIVES: Volume perfusion CT (VPCT) of the liver provides functional information but is associated with increased radiation exposure and often requires additional multiphasic CT acquisitions. Photon-counting CT (PCCT) may enable low-dose one-stop imaging by generating diagnostic morphological images directly from perfusion datasets. To evaluate the image quality of single-phase and fused noncontrast and contrast-enhanced images generated from photon-counting CT (PCCT)-based liver dynamic volume perfusion CT (VPCT) for liver morphologic assessment. MATERIALS AND METHODS: In this prospective study, 62 patients with liver disease underwent true noncontrast PCCT, liver VPCT, and low-dose delayed-phase imaging. Single-time-point noncontrast, arterial-phase, and portal venous-phase images were reconstructed from the VPCT dataset using virtual monoenergetic image (VMI, 40-70 keV) and Threshold 3D (T3D) reconstruction. Fused T3D images were generated from multiphase perfusion data. Image quality was evaluated using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image-quality scores. Radiation dose was recorded. RESULTS: The one-stop imaging protocol yielded a lower effective dose than the simulated conventional four-phase protocol combined with perfusion imaging (25.9 ± 6.7 mSv vs 31.9 ± 8.5 mSv, P < 0.05). Compared with true noncontrast images, fused noncontrast images showed higher SNR (8.6 ± 3.0 vs 7.0 ± 1.9) and CNR (1.5 ± 1.2 vs 1.0 ± 0.8) (P < 0.05). Although subjective image-quality scores for perfusion-derived noncontrast images were lower than those for true noncontrast images, all remained diagnostically acceptable (score ≥ 3). In the arterial phase, fused images showed the lowest image noise (7.5 ± 2.7 HU), while 40-keV VMI provided the highest CNR (70.4 ± 24.0). In the portal venous phase, fused images achieved the lowest noise (8.8 ± 2.8 HU) while maintaining relatively high CNR (10.4 ± 7.8). Except for 40-keV and 50-keV portal venous-phase images, all reconstructed arterial- and portal venous-phase images achieved diagnostically acceptable subjective scores (≥3). CONCLUSION: PCCT-based liver VPCT one-stop imaging reduces radiation exposure while providing diagnostically acceptable morphologic images. The optimal reconstruction of noncontrast and contrast-enhanced images varies by imaging phase, supporting a phase-specific image optimization strategy for liver morphologic assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feasibility of one-stop multi-energy dynamic photon-counting perfusion CT for resectable HCC evaluation: lesion detection and histopathological correlations.Insights into imaging · 2026
- Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.Diagnostics (Basel, Switzerland) · 2026
- Adult Abdominal Photon-Counting CT Protocols: A Multiinstitutional Consensus of the Society of Abdominal Radiology Photon-Counting Detector CT Emerging Technology CommissionAmerican Journal of Roentgenology · 2025
- Uniform quantification of hepatic fat fraction across body sizes using photon-counting CT.European journal of radiology · 2026
- Dynamic Multi-Phase-Fused Photon-Counting CT for Pre-TACE Feeding Artery Mapping and DSA Procedural Road-Mapping in Hepatocellular Carcinoma.Cancers · 2026
- Robust Liver Steatosis Quantification Using Photon-Counting CT in Comparison to PDFF: Validation across Protocols and Cohorts.Academic radiology · 2026