Multicenter Comparative Validation of an nnU-Net-Based Automated CT Radiomics Workflow for Acute Pancreatitis Severity Prediction.
Boyao Hou, Wen Feng, Wenxue Li, Wenjing He, Junxian Gu, Yaxin Deng, Hong Deng
School of Medical Imaging, North Sichuan Medical University, Nanchong, China (B.H., W.F., W.L., W.H., J.G., and H.D.). · Innovation Center of Science and Technology, North Sichuan Medical College, Nanchong, China (Y.D.).
Key points
From the paper's conclusion- The nnU-Net-based automated segmentation-radiomics workflow showed no significant difference in discrimination compared with the expert manual workflow in the internal test cohort. It also maintained moderate discrimination across two external cohorts. These findings support the feasibility of reducing dependence on manual pancreatic segmentation, although the present analysis does not establish formal equivalence or interchangeability.
Abstract
RATIONALE AND OBJECTIVES: Computed tomography radiomics has shown potential for predicting acute pancreatitis (AP) severity, but conventional workflows depend on labor-intensive expert pancreatic segmentation. This study evaluated a no-new-Net (nnU-Net)-based automated segmentation-radiomics workflow against an expert manual-segmentation workflow, using AP severity classification as the downstream task, and assessed the automated workflow externally. MATERIALS AND METHODS: This retrospective multicenter study included patients with AP from Center A (n = 214), Center B (n = 56), and Center C (n = 42). Expert manual pancreatic masks served as reference annotations for nnU-Net training and as the comparator for the radiomics workflow. After selecting the optimal nnU-Net configuration, radiomics features were extracted separately from manual and automated regions of interest, and AP severity classifiers were developed using the same analytical framework. Discrimination between the two workflows was compared in the independent internal test cohort using the area under the curve (AUC) and the paired DeLong test, with Benjamini-Hochberg false discovery rate (FDR) and Bonferroni corrections applied to P values. RESULTS: In the internal test cohort, the Light Gradient Boosting Machine classifier achieved AUCs of 0.799 (95% confidence interval (CI), 0.683-0.915) and 0.733 (95% CI, 0.593-0.873) with manual and automated segmentations, respectively. The absolute AUC difference was 0.066, and the paired DeLong comparison was not statistically significant after FDR correction (FDR-adjusted p = 0.360; Z = 1.1755, unadjusted p = 0.2398). The automated workflow achieved AUCs of 0.784 (95% CI, 0.653-0.915) in Center B and 0.715 (95% CI, 0.559-0.871) in Center C. The selected 2D nnU-Net achieved a mean Dice coefficient of 0.798 during five-fold cross-validation and 0.726 in the independent internal test cohort. CONCLUSION: The nnU-Net-based automated segmentation-radiomics workflow showed no significant difference in discrimination compared with the expert manual workflow in the internal test cohort. It also maintained moderate discrimination across two external cohorts. These findings support the feasibility of reducing dependence on manual pancreatic segmentation, although the present analysis does not establish formal equivalence or interchangeability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated CT Volumetry of Peripancreatic Collections for Risk Stratification in Acute Pancreatitis: A Multicenter Retrospective Study.Academic radiology · 2026
- CT-based machine learning and multimodal prediction in acute pancreatitis: a narrative review.Abdominal radiology (New York) · 2026
- Interpretable machine learning model based on non-contrast computed tomography within 24 hours of admission for early prediction of the risk of severe deterioration of acute pancreatitis.Quantitative imaging in medicine and surgery · 2026
- A Nomogram for Early Prediction of Infected Pancreatic Necrosis Based on Contrast-Enhanced CT Radiomics and Inflammatory IndicatorsJournal of Inflammation Research · 2025
- CT-based Multimodal Model for Early Severity Prediction in Hyperlipidemic Acute Pancreatitis: A Multicenter Study.Academic radiology · 2026
- Multi-centre Validation of Automated Outer-to-Outer Wall Segmentation of Infrarenal Abdominal Aortic Aneurysms Using a nnU-Net Based Model.Journal of imaging informatics in medicine · 2026