Objective Assessment of Intermittent Exotropia Magnitude and Control Using the Binocular Eye Alignment Monitor.
Erin C Jenewein, Christopher J Morris, Mitchell Scheiman, Tara L Alvarez
Pennsylvania College of Optometry at Drexel University, Elkins Park, Pennsylvania, USA. ej468@drexel.edu. · Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, USA.
Key points
From the paper's conclusion- The notable differences in control observed with the BEAM compared to current clinical measures suggest that office control scores and prolonged objective monitoring may capture different aspects of IXT control. Objective monitoring over extended periods may be a valuable complement to traditional clinical assessment in both research and clinical care.
Abstract
PURPOSE: To compare an objective assessment of intermittent exotropia (IXT) control and deviation size using the binocular eye alignment monitor (BEAM) to standard clinical assessments. METHODS: IXT control and deviation size were evaluated in 15 participants aged 8-35 years. Participants completed two visits that included a 90-min BEAM eye movement recording at a distance (6 m) to evaluate distance IXT size and control of the deviation objectively. IXT control was assessed using the mean of three measurements of the IXT Office Control Scale, and the deviation size was measured with the prism alternate cover test (PACT). RESULTS: The mean IXT control score in the IXT participants was 2.2 ± 1 points, which was weakly correlated with the percentage of time strabismic as measured by the BEAM (Spearman's correlation coefficient = 0.29; p = 0.30). Distance PACT and mean BEAM deviation size demonstrated a moderate, non-significant association (ρ = 0.47, p = 0.08). BEAM measurements were consistently smaller than PACT measurements. IXT distance control (0.44; 95% CI: 0.04-0.80; p = 0.03) and the median deviation size measured by the BEAM (z = -2.1, p = 0.03) were significantly different between visits 1 and 2 (z = -2.1, p = 0.03); however, the percentage of time deviated (BEAM) was not significantly different between the two study visits (z = -0.63; p = 0.50). CONCLUSIONS: The notable differences in control observed with the BEAM compared to current clinical measures suggest that office control scores and prolonged objective monitoring may capture different aspects of IXT control. Objective monitoring over extended periods may be a valuable complement to traditional clinical assessment in both research and clinical care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Interocular Symmetry in Anterior Segment Parameters in Children With Intermittent Exotropia Observed by CASIA2 AS-OCT.Journal of ophthalmology · 2026
- Impact of preoperative deviation control on one-year motor results after intermittent exotropia surgery.Therapeutic advances in ophthalmology · 2026
- Analysis of Convergence and Divergence Using an Eye Tracker in Acquired Comitant Esotropia.Investigative ophthalmology & visual science · 2026
- Distance-dependent changes in deviation control after alternate occlusion therapy in children with intermittent exotropia: a retrospective pilot study.Strabismus · 2026
- Progression of intermittent exotropia in surgical and non-surgical patients: a retrospective cohort study.Strabismus · 2026
- Agreement between digital ocular alignment measurement devices and the prism alternate cover test in horizontal strabismus.International ophthalmology · 2026