Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

Colorimetric chemiluminescent bifunctional sensor for sensitive detection of choline in milk samples.

Yongning Song, Jingkang Li, Yunmei Wu, Ximin Mai, Yanfu Huan, Pinyi Ma, Daqian Song, Qiang Fei

College of Chemistry, Jilin Province Research Center for Engineering and Technology of Spectral Analytical Instruments, Jilin University, Qianjin Street 2699, Changchun, 130012, China. · College of Chemistry, Jilin Province Research Center for Engineering and Technology of Spectral Analytical Instruments, Jilin University, Qianjin Street 2699, Changchun, 130012, China. feiqiang@jlu.edu.cn.

Key points

From the paper's conclusion
  • This sensor quantifies choline linearly from 10 to 100 μM with LOD of 6.32 μM, while the colorimetric mode shows linear response within 0-200 μM with an instrumental LOD of 18.4 μM and a naked-eye detection limit of 50 μM.

Abstract

Rapid sensors for choline detection in food samples are highly desired. Three quinoline-based sensors (KL-1/2/3) were synthesized, among which KL-1 with favorable chemiluminescence performance was selected. For the first time, quinoline skeletons were utilized to construct TMB-free dual-mode colorimetric-chemiluminescence sensors. Choline oxidase produces H₂O₂ from choline, triggering simultaneous luminescence and color fading on KL-1. This sensor quantifies choline linearly from 10 to 100 μM with LOD of 6.32 μM, while the colorimetric mode shows linear response within 0-200 μM with an instrumental LOD of 18.4 μM and a naked-eye detection limit of 50 μM. This dual-mode sensor tolerates milk-matrix interferences and provides satisfactory recoveries upon simple sample dilution. This work offers a simple dual-mode sensor for rapid food choline detection.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers