A colorimetric and ratiometric fluorescence dual-mode biosensor based on manganese-doped carbon dots for the detection of chloramphenicol residues.
Tongtong Li, Litao Chen, Jianing Sun, Jinyang Li, Jiayan Gao, Xue Gao
College of Food Science and Technology, Bohai University, Jinzhou, Liaoning Province, 121013, China. · College of Food Science and Technology, Bohai University, Jinzhou, Liaoning Province, 121013, China. huaxue_gaoxue@126.com.
Key points
From the paper's conclusion- This dual-mode strategy enables the sensitive detection of CAP via monitoring the absorbance intensity and the fluorescence ratio (F550 nm/F455 nm).
Abstract
A dual-mode (colorimetric/fluorometric) sensing system for monitoring chloramphenicol (CAP) residues has been developed. The detection system was constructed using Fe₃O₄ nanoparticles (Fe₃O₄ NPs) as magnetic separation carriers and Mn-doped carbon dots (Mn-CDs) as signal probes. Fe₃O₄ NPs were conjugated to the CAP aptamer (Apt) via amide linkages, and Mn-CDs were linked to the complementary DNA strand (cDNA).Subsequently, these two components were assembled through base complementarity. In the presence of CAP, the Mn-CDs-cDNA complex undergoes competitive dissociation due to the stronger specific binding between CAP and the aptamer compared with base pairing. Following magnetic separation, the released Mn-CDs-cDNA complex in the supernatant catalyzes the oxidation of o-phenylenediamine (OPD) to 2,3-diaminophenazine (DAP), generating a colorimetric signal with an absorption peak at 450 nm. Simultaneously, a ratiometric fluorescence signal is achieved through the inner filter effect (IFE). DAP formation enhances fluorescence at 550 nm while quenching the blue emission of Mn-CDs at 455 nm. This dual-mode strategy enables the sensitive detection of CAP via monitoring the absorbance intensity and the fluorescence ratio (F550 nm/F455 nm). Under optimized detection conditions, the linear range for the colorimetric mode was 0.002-2 µmol L-1 with a detection limit of 11.6 nmol L-1; the linear range for the fluorometric mode was 0.005-6 µmol L-1 with a detection limit of 4.02 nmol L-1. This method demonstrates reliable performance for the detection of CAP residues in food samples. The dual-mode sensing strategy offers enhanced sensitivity and provides a promising analytical approach for food safety monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multi-mode biosensor based on T-Hg2+-T structure for the detection of Hg2+ and chloramphenicol residues.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Heterobimetallic-doped carbon dots for colorimetric, fluorescent and photothermal sensing of total antioxidant capacity in fruits.Mikrochimica acta · 2026
- A carbon dots-doped europium-MOF for dual-signal ratiometric fluorescence and colorimetric detection of flumequine.Mikrochimica acta · 2026
- A ratiometric fluorescence and smartphone-assisted dual-mode sensing platform based on dual-emissive carbon quantum dots for highly sensitive and visual monitoring of ciprofloxacin in food samples.Food chemistry · 2026
- Bimetallic-doped carbon dots-driven three-mode sensor Array for tetracycline antibiotics identification.Food chemistry · 2026
- A dual-mode colorimetric and fluorescent sensing platform based on MnO2 nanosheets for sensitive detection of Escherichia coli.Mikrochimica acta · 2026