Application of cellulose sponge modified by polypyrrole for thin film microextraction of polycyclic aromatic hydrocarbons.
Mohammad Saraji, Mahsa Aghaei, Salman Javadian
Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran. saraji@iut.ac.ir. · Department of Chemistry, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
Key points
From the paper's conclusion- Extraction of analytes from sample solution to the cellulose/poly pyrrole film was performed through π-π interactions between the sorbent and polycyclic aromatic hydrocarbons (PAHs).
Abstract
In this work, a flexible and environmentally compatible thin film, consisted of cellulose and polypyrrole, was prepared and used as a new thin film microextraction sorbent for adsorption and determination of trace amount of methylnaphthalene, anthracene and pyrene from aqueous samples. Analytes were determined by gas chromatography equipped with a flame ionization detector. polypyrrole was used as a modifier due to its porous structure and good mechanical stability in aqueous solution. Pyrrole monomers deposited on cellulosic substrate were polymerized through oxidative chemical polymerization. Extraction of analytes from sample solution to the cellulose/poly pyrrole film was performed through π-π interactions between the sorbent and polycyclic aromatic hydrocarbons (PAHs). Extraction efficiency was studied by changing parameters such as desorption solvent, time of desorption, volume of desorption solvent, salt concentration, temperature and extraction time were optimized. The detection limits of 1.40, 0.60 and 0.45 µg L-1 were obtained for methylnaphthalene, anthracene and pyrene, respectively. The method showed good linearity in the concentration range of 4-3000, 2-1000, and 1-500 µg L-1 for methylnaphthalene, anthracene and pyrene, respectively. Intra- and inter-day precision were in the range of 6.0-8.0% and 12.0-15.0%, respectively. Finally, PAHs were determined in real samples by this method. Recovery for real samples was in the range of 53-102%.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Preparation of a Filtrable Polypyrrole‐Modified Cellulose Material for Solid‐Phase Extraction and Detection of 15 Nonsteroidal Anti‐Inflammatory Drugs in WaterChemistrySelect · 2026
- Polymer-embedded thin films of a pyrene chalcone-based small molecule for vapour-phase detection of picric acid.RSC advances · 2026
- Electron-deficient carborane covalent organic framework as an efficient SPME coating for enhanced determination of polycyclic aromatic hydrocarbons.Journal of hazardous materials · 2026
- In situ electro-polymerized polyaniline thin film on highly porous carbon fiber felt for extraction and chromatographic detection of non-steroidal anti-inflammatory drugsScientific Reports · 2026
- Porous pyrene-based HOF-102 coating for solid-phase microextraction of nitroaromatic compounds in beverage samples.Mikrochimica acta · 2026
- Hydrophobic natural deep eutectic solvent-based single-drop microextraction for the determination of polycyclic aromatic hydrocarbons in water by gas chromatography-mass spectrometry.Journal of chromatography. A · 2026