A lightweight hybrid LSTM–GNN framework with context-aware risk calibration for physiological monitoring
Mohamed Mostafa Abdulali
Key points
From the paper's conclusion- These findings support reproducible, lightweight cross-database evaluation under the specified harmonization protocol, while limiting the claims to software-level computational feasibility rather than physical edge deployment, independent multimodal sensing, autonomous adaptive behavior, or established clinical utility.
Abstract
The Internet of Medical Things requires physiological monitoring systems that balance temporal signal dynamics, relational structure, and computational efficiency. This study presents a lightweight hybrid LSTM–GNN framework for binary ECG screening, integrating explicit graph message passing, temporal modelling, and an ECG-derived proxy-context node. The framework was evaluated on 47 MIT-BIH records using strict record-wise splitting, preprocessing designed to avoid information leakage, and a fixed 0.50 decision threshold across five random seeds. In addition, an external cross-database evaluation was conducted on the INCART database without fine-tuning or threshold tuning, using a harmonized binary label mapping. On MIT-BIH, the Full Hybrid condition achieved the highest mean Accuracy (0.8991 ± 0.0363) and F1-score (0.8121 ± 0.0573), together with the lowest false-alarm rate (0.1129 ± 0.0523) among the evaluated conditions. On the external INCART database, the Full Hybrid condition achieved a mean Accuracy of 0.8801 ± 0.0151 and ROC-AUC of 0.9065 ± 0.0227 under the fixed external-test protocol. The ablation analysis indicated measurable contributions from the combined representations, while the context-permutation analysis showed that the proxy context should not be interpreted as an independent modality. In addition, software-level runtime profiling using ONNX Runtime demonstrated software-level portability characteristics and runtime efficiency on a standard CPU environment, with 8066 parameters, an approximately 36.1-kB model file, and a median CPU latency of 0.076 ms. The reported variability summarizes performance variation across five random seeds reflecting training stability, and should not be interpreted as patient-level inferential confidence intervals. These findings support reproducible, lightweight cross-database evaluation under the specified harmonization protocol, while limiting the claims to software-level computational feasibility rather than physical edge deployment, independent multimodal sensing, autonomous adaptive behavior, or established clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A lightweight reliability- and confidence-aware selective ECG framework for degraded remote monitoring.Computers in biology and medicine · 2026
- Intelligent 12-Lead ECG Monitoring System for Real-Time Cardiac Surveillance: Design and Experimental Evaluation of the Moroccan VitaTrack GeoMed PrototypeTechnologies · 2026
- Patient-adaptive and clinically interpretable arrhythmia detection from ECG using lightweight hybrid deep learning.Biomedical engineering letters · 2026
- SmartHealth-IoT: a simulation-based IoT remote patient monitoring framework using virtual wearable physiological data streamsScientific Reports · 2026
- Multimodal Integration of Ambulatory ECG and Clinical Features for Sudden Cardiac Death and Pump Failure Death PredictionmedRxiv · 2026
- A long short-term memory network with SHAP interpretability for dynamic prediction of ICU delirium: development and external validationFrontiers in Digital Health · 2026