Treatment of Displaced Fracture Neck of Femur by Conventional Parallel Screws (CFIX) and Biplane Double-Supported Screws (BDSF) in Adults: A Prospective Study.
Jishnu Prakash Baruah, Abhinab Gogoi, Kumar Madhurya Pratim
Department of Orthopaedics, Assam Medical College and Hospital, Dibrugarh, Assam India. · Department of Orthopaedics, Pragjyotishpur Medical College and Hospital, Guwahati, Assam India.
Key points
From the paper's conclusion- The BDSF technique demonstrated earlier union and better early functional outcomes compared with CFIX, with comparable overall union and complication rates. These findings suggest that BDSF may be a promising alternative fixation option for displaced intracapsular neck of femur fractures.
Abstract
INTRODUCTION: Intracapsular fracture neck of femur has been a challenge to orthopedic surgeons and internal fixation with conventional technique is often associated with poor outcomes. The BDSF technique introduced by Filipov has shown encouraging clinical outcomes and reduced fixation failure rates in published series. However, comparative data between BDSF and conventional cancellous screw fixation (CFIX) remain limited. This study aimed to compare the clinical and radiological outcomes of both fixation modalities. METHODOLOGY: A prospective comparative study was conducted for 2 years including 60 patients, treated with either BDSF (Group A, n = 30) was compared with CFIX method (Group B, n = 30) in displaced fracture neck of femur. Functional outcomes were assessed using Modified Harris Hip scoring system (HHS) and radiological outcome was assessed by serial hip X-ray. RESULTS: 93.33% cases united post-operatively in group A and 90% cases in Group B but it was not statistically significant. All the failure cases had Garden IV fractures & posterior comminution. Average union time in BDSF method was 12.55 weeks compared to 14.68 weeks in CFIX (p < 0.05). Significantly superior functional outcomes at 1 month and 3 months in BDSF group (mean HHS 85.28 and 87.80) compared to CFIX group (mean HHS 72.20 and 82.07) (p < 0.05). CONCLUSION: The BDSF technique demonstrated earlier union and better early functional outcomes compared with CFIX, with comparable overall union and complication rates. These findings suggest that BDSF may be a promising alternative fixation option for displaced intracapsular neck of femur fractures.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dynamic hip screw versus cannulated cancellous screws fixation for osteosynthesis of femoral neck fractures in adults: a retrospective comparative study.International journal of burns and trauma · 2026
- Comparison of internal fixation outcomes in young femoral neck fractures: three cannulated compression screws versus the femoral neck system.Frontiers in surgery · 2026
- Comparative efficacy of the femoral neck system, cannulated cancellous screws combined with medial buttress plate, and cannulated cancellous screws in the treatment of femoral neck fractures in young and middle-aged adults.Injury · 2026
- Early mechanical failure patterns after femoral neck fixation with the femoral neck system and dynamic hip screw.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Femoral Neck System for young and middle-aged adult femoral neck fractures: a trade-off between reduced lateral irritation and increased neck shortening.Hip international : the journal of clinical and experimental research on hip pathology and therapy · 2026
- Comparative outcomes of cannulated screws, dynamic hip screws and the femoral neck system for transcervical femoral neck fractures. a retrospective cohort study.Orthopaedics & traumatology, surgery & research : OTSR · 2026