From the paper's conclusion
  • To address this, we propose CMA-Net (Cross-scale Mamba Alignment Network), a lightweight hybrid architecture utilizing parallel Mamba blocks.

Abstract

UNLABELLED: Electronic fetal monitoring via cardiotocography (CTG) is essential for evaluating fetal status, yet recorded traces are frequently corrupted by sensor artifacts. Additionally, conventional deep learning models struggle to balance long-range sequence modeling with the computational constraints of clinical edge devices. To address this, we propose CMA-Net (Cross-scale Mamba Alignment Network), a lightweight hybrid architecture utilizing parallel Mamba blocks. The proposed network extracts multi-scale spatial features from 2D trace images via a DenseNet-121 backbone, refining them with a Coordinate Attention mechanism. These feature maps are vertically decoupled into independent fetal heart rate (FHR) and uterine contraction (UC) streams. After an hourglass bottleneck reduces dimensionality, parallel Mamba blocks model temporal dynamics with linear complexity. A cross-scale attention mechanism then aligns macroscopic baseline trends with microscopic variations within each stream. Finally, the concatenated features are refined via a Selective Channel Adaptive Regulation (SCAR) module to suppress artifact-driven responses. Evaluated through 5-fold cross-validation on a balanced dataset of 3036 authentic clinical recordings, CMA-Net achieved an Area Under the Curve (AUC) of 94.68% and an F1-Score of 88.13%, maintaining a constrained parameter footprint of 8.37 M. Compared with the generic visual models evaluated in this study, CMA-Net demonstrated a sensitivity of 89.59% and effectively minimized false negative predictions without increasing the computational burden. This favorable engineering trade-off suggests the model's potential to enhance the safety margin for anomaly detection on resource-constrained clinical edge devices. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at https://doi.org/10.1007/s13534-026-00612-w.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers