Biomedical physics & engineering express

MRAST-Net: A Lightweight Multi-Receptive-Field Residual Temporal Network for 12-Lead ECG Classification.

Mingliang Wang, Mujun Zang, Tong Liu, Shusen Zhou, Chanjuan Liu, Qingjun Wang

Ludong University, Hongqi Middle Road 186, Zhifu District, Yantai, Shandong, 264025, China. · Ludong University, Hongqi Middle Road 186,Zhifu District, Yantai, Shandong, 264025, China.

Key points

From the paper's conclusion
  • To balance classification performance and lightweight deployment, this paper proposes MRAST-Net, a lightweight multi-receptive-field residual temporal network for 12-lead ECG classification.

Abstract

Electrocardiogram (ECG) signals play an important role in cardiovascular disease screening, clinical monitoring, and remote healthcare. However, existing high-performing ECG classification methods usually rely on complex deep learning architectures, which often involve a large number of parameters, high computational cost, and limited deployability in resource-constrained scenarios. To balance classification performance and lightweight deployment, this paper proposes MRAST-Net, a lightweight multi-receptive-field residual temporal network for 12-lead ECG classification. The proposed model first employs a lead mixing layer to enable cross-lead information interaction. It then uses a lightweight multi-scale residual depthwise convolution module to extract local waveform morphology features under different receptive fields, while an efficient channel attention mechanism is introduced to enhance informative channel responses. On this basis, a temporal convolutional network is further incorporated to model long-range dynamic dependencies, and attentive statistics pooling is used to aggregate global statistical features for final multi-label classification. Experiments on two public 12-lead ECG datasets, PTB-XL and CPSC-2018, show that the proposed model achieves AUC scores of 93.12 $\pm$ 0.16\%, 92.29 $\pm$ 0.80\%, and 92.62 $\pm$ 0.51\%, and ACC scores of 89.17 $\pm$ 0.09\%, 96.40 $\pm$ 0.02\%, and 97.72 $\pm$ 0.07\% on the 5-superclass, 23-subclass, and 44-diagnostic-class tasks of PTB-XL, respectively. On CPSC-2018, MRAST-Net achieves an AUC of 96.57 $\pm$ 0.43\% and an ACC of 96.59 $\pm$ 0.26\% under 5$\times$3 nested cross-validation. These results demonstrate that MRAST-Net achieves competitive classification performance while maintaining a low parameter scale, indicating its potential for deployment in resource-constrained scenarios such as portable monitoring devices, real-time assisted diagnosis, and primary healthcare.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

MRAST-Net: A Lightweight Multi-Receptive-Field Residual Temporal Network for 12-Lead ECG Classification — Science Skim