Multiplexer-based system development for multichannel neurochemical sensing.
Haeun Kwon, Sangmun Hwang, Dong Pyo Jang
Department of Electronic Engineering, Hanyang University, Seoul, Republic of Korea. · Department of Biomedical Engineering, Hanyang University, Seoul, Republic of Korea.
Abstract
UNLABELLED: Simultaneous measurement of neurotransmitters in multiple individuals enables more accurate comparison of behavioral and pharmacological responses between subjects. In this study, we developed a system capable of multichannel electrochemical measurements using multiplexers (MUXs). Although MUXs are widely used in analog circuits, their parasitic characteristics can degrade the accuracy of current-based electrochemical systems. Therefore, the effect of parasitic components on electrochemical measurements was examined through dopamine detection experiments and simulations using fast-scan cyclic voltammetry (FSCV). The experimental and simulation results showed that parasitic capacitance increased the background current and noise. In addition, a substantial background current increase of more than 5% was observed when the capacitance exceeded 50 pF. Based on the simulation results, MUX devices such as ADG1206 and TMUX6119, which have parasitic capacitance below 50 pF, were selected, and an optimized system was developed and evaluated. Verification experiments showed that the background current and noise of the optimized system were not significantly different from those of the standalone transimpedance amplifier (TIA) system. High channel uniformity and long-term stability were also achieved, with normalized root mean square error below 0.5%, normalized deviation within ± 3%, and Z-scores within ± 1. In dopamine detection experiments, rapid and consistent current responses verified the system's reliable detection performance. With a 16-channel MUX configuration, the system supports multichannel simultaneous measurements using user-defined waveforms, including FSCV. It enables up to 11 channels at 10 Hz FSCV and up to 16 channels at 7 Hz FSCV. The proposed hardware can be integrated into existing systems, enabling scalable multichannel capability without the need for extensive redesign. Based on our experimental results, we demonstrated that the developed multichannel system provides reliable and effective detection. This study provides a foundational guideline for MUX-based electrochemical measurement systems. The proposed approach can support efficient experimental design in fields such as behavioral neuroscience and pharmacology by enabling simultaneous multichannel measurements. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13534-026-00554-3.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Dual-Mode Neural Amplifier Array for Biopotential and FSCV-Based Neurochemical Measurements.Biosensors · 2026
- Zwitterionic Polymer Coating Enabled Chronic Dopamine Sensing and Electrophysiology Recording in Free-Moving Mice.Advanced healthcare materials · 2026
- Electrode multiplexing enables scalable continuous molecular monitoring in interstitial fluid.Biosensors & bioelectronics · 2026
- A Wireless Neural-Interface SoC with Multimodal Chemical and Electrical Recording Capabilities.IEEE transactions on biomedical circuits and systems · 2026
- Flexible Multimodal Neural Probe with Integrated Three-Electrode Aptameric Sensing for In Vivo Monitoring of Dopamine Dynamics and Neural Activity.ACS chemical neuroscience · 2026