Ultrasound swallowing assessment: the impact of image post-processing on measurement reliability.
Katharina Winiker, Sruthy Vijayan, Alan Brook, Maggie-Lee Huckabee
Department of Research and Development, Swiss University of Speech and Language Sciences (hlo), Bahnhofplatz 2, St.Gallen, 9000, Switzerland. katharina.winiker@hlo.ch. · The University of Canterbury Rose Centre for Stroke Recovery and Research, 249 Papanui Rd, Private Bag 4737, Christchurch, 8140, New Zealand.
Key points
From the paper's conclusion- This study explored the impact of ultrasound image post-processing on measurement reliability of swallowing parameters.
Abstract
The use of ultrasound for swallowing assessment is promising; yet its application has not translated from research into routine clinical practice. While sufficient reliability is key to support implementation, insufficient reliability for swallowing measures has been documented for pocket-sized ultrasound technology. Image quality, a known prerequisite for reliability, may be compromised in small-sized ultrasound technology. This study explored the impact of ultrasound image post-processing on measurement reliability of swallowing parameters. Ultrasound images (n = 30) of hyoid excursion, thyrohyoid approximation, and submental muscles were selected from a database of images previously collected using a pocket-sized ultrasound system in healthy adults. For this pilot study, images were measured at two time points by four raters with and without experience in ultrasound imaging. For those with experience, their engagement with ultrasound was gained in the context of research data collection, rather than daily clinical practice. At both time points, raters measured each image once with and once without the application of an image processing software that was developed to improve image contrast and image features. ICCs were calculated using linear mixed effects analyses to evaluate inter- and intra-rater measurement reliability. Intra- and inter-rater ICCs were similar for processed and unprocessed images for most parameters of interest with a few ICCs being higher or lower for processed images compared to unprocessed images. There is no strong evidence to suggest general beneficial effects of post-processing on ultrasound swallowing measurement reliability. These preliminary pilot data provide a foundation and directions for further research to clarify the role of ultrasound image post-processing for swallowing evaluation. Further refinement of processing methods may produce improved results.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ultrasound Parameters for Assessment and Rehabilitation Monitoring of Post-Stroke Dysphagia: A Narrative Review.Life (Basel, Switzerland) · 2026
- Intra- and Inter-Operator Reliability of Internal Jugular Vein Ultrasound Image Acquisition by Ultrasound-Naive Nurses.Healthcare (Basel, Switzerland) · 2026
- Can laryngeal ultrasound detect laryngeal movements during mechanically assisted cough?ERJ open research · 2026
- Ultrasound innovations in diaphragm assessment: an integrative review of expanding clinical applicationsEuropean Respiratory Review · 2025
- Within-Session Intra-Observer Reproducibility of Spleen Stiffness Measured by Endoscopic Ultrasound Point Shear-Wave Elastography: A Prospective Single-Operator Study.Diagnostics (Basel, Switzerland) · 2026
- Optimization and Device-Level Validation of the i-Phagia Surface Electromyography Submental Sensor Patch for Swallowing Monitoring: A Randomized Crossover Design StudyJournal of Speech Language and Hearing Research · 2026