Dialysis catheter insertion in the prone position in a patient with severe hypoxemia and hemodynamic instability: a case report.
Mayur Chillal, Kiyan Heybati, Ben Baldacchino, Jan O Friedrich
Department of Critical Care Medicine, Unity Health/St. Michael's Hospital, Toronto, ON, Canada. mayurramakrishna.chillal@unityhealth.to. · Department of Internal Medicine, Mayo Clinic, Rochester, MN, USA.
Key points
From the paper's conclusion- Prone central venous dialysis catheter insertion, using a modified anterior approach, can be a potential option for patients with severe hypoxemia in prone position. This unusual and infrequently described approach to dialysis catheter insertion requires further study to better characterize potential associated complications.
Abstract
PURPOSE: Central venous access in the prone position has historically been challenging, but recent advancements, particularly following the COVID-19 pandemic, have made this approach increasingly feasible. The internal jugular vein (IJV) is one of the most accessible sites for central venous cannulation in patients in the prone position, especially under ultrasound guidance. In this case report, we sought to describe the feasibility and step-by-step approach of central venous dialysis catheter insertion under ultrasound guidance in a patient with critical illness who was transferred in prone position and required urgent plasmapheresis. TECHNICAL FEATURES: A 69-yr-old female patient was transferred with severe hypoxemic respiratory failure (partial pressure of oxygen [PaO2]/ fraction of inspired oxygen [FIO2] ratio, 70), new-onset pancytopenia, hemoptysis, and acute renal failure requiring dialysis catheter insertion. Due to inability to tolerate supine positioning and hemodynamic instability, the procedure was performed prone. For right IJV access, the head was slightly rotated contralaterally, the shoulders elevated with an extra pillow, and the bed placed in 20° Trendelenburg position. Placing a linear ultrasound probe transversely, we visualized the sternocleidomastoid muscle, IJV, and carotid artery. We used a modified anterior approach for needle insertion, targeting the lateral wall of the IJV instead of the anterior wall as done in the traditional anterior approach. Once the vein was punctured, the 15-cm, 12-Fr double-lumen dialysis catheter was inserted using the Seldinger technique. CONCLUSIONS: Prone central venous dialysis catheter insertion, using a modified anterior approach, can be a potential option for patients with severe hypoxemia in prone position. This unusual and infrequently described approach to dialysis catheter insertion requires further study to better characterize potential associated complications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of ultrasound-guided oblique-axis versus short-axis approaches for right internal jugular vein cannulation in the left decubitus position: a prospective, randomized, single-center trial.BMC anesthesiology · 2026
- Accuracy and Concordance of Agitated Saline Bubble-Enhanced Ultrasound versus Chest Radiography by Internal Jugular Insertion Site.Journal of visualized experiments : JoVE · 2026
- Axillary right vein percutaneous ballooning in hemodialysis catheter replacement: A case report.The journal of vascular access · 2026
- Unexpected Position of a Hemodialysis Catheter.Cureus · 2026
- Tunneled hemodialysis catheter placement using anatomical landmarks and vein ultrasound: Clinical experience.The journal of vascular access · 2026
- Ultrasound-Guided, Guidewire-Assisted Long Peripheral Catheter in the Great Saphenous Vein for Bilateral Upper Limb Fracture Surgery: A Case Report.Case reports in anesthesiology · 2026