Axillary right vein percutaneous ballooning in hemodialysis catheter replacement: A case report.
Ferrara Gaetano, Aucella Francesco, Nasuto Michelangelo, Gatta Giuseppe, Ciccarese Giovanni, Aucella Filippo
Department of Nephrology and Dialysis, Scientific Institute for Research and Health Care, Fondazione Casa Sollievo della Sofferenza, San Giovanni Rotondo, Italy. · Radiology Interventional Unit, Scientific Institute for Research and Health Care, Fondazione Casa Sollievo della Sofferenza, San Giovanni Rotondo, Italy.
Key points
From the paper's conclusion- In this report, we describe the replacement of a tunneled hemodialysis catheter in the right axillary vein following percutaneous balloon angioplasty of an early axillary vein stenosis that had developed 6 months after the first catheter placement.
Abstract
Reliable vascular access remains a key point of hemodialysis therapy although each patient's journey through chronic kidney disease is unique. The 2019 Kidney Disease Outcomes Quality Initiative (KDOQI) vascular access guidelines introduced a patient-centered approach, emphasizing individualized vascular access planning based on each patient's clinical characteristics, comorbidities, life expectancy, and treatment goals. Vascular access troubleshooting is required when the creation of a native arteriovenous fistula or prosthetic graft is not feasible, necessitating the use of tunneled central venous catheters inserted into central veins such as the internal jugular, subclavian, axillary, or femoral ones. The internal jugular vein is generally considered the preferred access site. However, when its use is precluded by thrombosis, stenosis, or unfavorable cervical anatomy, the axillary vein represents a valuable alternative. In this report, we describe the replacement of a tunneled hemodialysis catheter in the right axillary vein following percutaneous balloon angioplasty of an early axillary vein stenosis that had developed 6 months after the first catheter placement. This strategy was adopted because all other upper central venous access sites were unavailable owing to right internal jugular vein stenosis and previous thrombosis of the brachiocephalic vein. Post-procedural chest radiography confirmed the correct positioning of the catheter tip within the right atrium site. The patient successfully resumed maintenance hemodialysis without further catheter dysfunction during follow-up. This case highlights the feasibility of percutaneous balloon angioplasty of a previously cannulated axillary vein to preserve vascular access and facilitate catheter replacement in hemodialysis patients with multiple comorbidities and severely limited central venous access options.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Tunneled hemodialysis catheter placement using anatomical landmarks and vein ultrasound: Clinical experience.The journal of vascular access · 2026
- Percutaneous extra-anatomical bypass stenting for AVF elbow perforating vein stenosis with venous hypertension.The journal of vascular access · 2026
- Unexpected Position of a Hemodialysis Catheter.Cureus · 2026
- Accuracy and Concordance of Agitated Saline Bubble-Enhanced Ultrasound versus Chest Radiography by Internal Jugular Insertion Site.Journal of visualized experiments : JoVE · 2026
- Adherence to KDOQI vessel preservation guidelines in chronic kidney disease: A 5-year retrospective single-institution review of device and vein selection.The journal of vascular access · 2026
- Overcoming Central Venous Occlusion: The First HeRO Graft Procedure in the Baltic States.Journal of clinical medicine · 2026