Comprehensive comparison of echocardiographic and invasive hemodynamics in a real-world pulmonary hypertension cohort.
Jamilah S AlRahimi, Alhanouf Alotaibi, Alhanouf Bagais, Omniah Bamardouf
Department of Cardiology, King Abdulaziz Medical City, Ministry of National Guard Health Affairs, P.O. Box 9515, Jeddah, 21423, Saudi Arabia. alrahimija@gmail.com. · King Abdullah International Medical Research Center, P.O. Box 9515, Jeddah, 21423, Saudi Arabia.
Key points
From the paper's conclusion- In a real-world, mixed-etiology PH cohort, TTE reliably identifies elevated pulmonary pressures but lacks precision for exact hemodynamic quantification. While valuable for screening, TTE cannot replace RHC for definitive diagnosis or hemodynamic classification, supporting a complementary diagnostic approach.
Abstract
BACKGROUND: Transthoracic echocardiography (TTE) is the preferred initial modality for evaluating suspected pulmonary hypertension (PH), yet its accuracy compared with right heart catheterization (RHC) remains variable, particularly in heterogeneous populations. We assessed multiple TTE-derived hemodynamic parameters against invasive measurements in a real-world PH cohort. METHODS: We retrospectively analyzed 125 adults who underwent TTE and RHC within 72 h (2020-2023). Hemodynamic parameters included systolic, diastolic, and mean pulmonary artery pressure (sPAP, dPAP, mPAP), pulmonary capillary wedge pressure (PCWP), and pulmonary vascular resistance (PVR). Mean PAP was estimated from pulmonary regurgitation velocity and right ventricular outflow tract acceleration time (AT). We evaluated correlation, Bland-Altman agreement, diagnostic accuracy, and inter-observer reproducibility. RESULTS: PH prevalence by RHC was 81.6%. TTE correlated moderately with RHC for sPAP (r = 0.62), mPAP (r = 0.48-0.50), PCWP (r = 0.51), and PVR (r = 0.50). TTE systematically underestimated pulmonary pressures and PVR, and overestimated PCWP, with wide limits of agreement across all parameters. Against RHC-defined PH (mPAP > 20 mmHg), TTE showed high positive predictive values for TTE sPAP ≥ 25 mmHg (86.4%) and AT-derived mPAP ≥ 20 mmHg (94.7%), but low to modest negative predictive values (53.3% and 38.8%, respectively). Doppler PVR showed high specificity (93.3%) and positive predictive value (97.5%), but modest sensitivity (60%). Inter-observer agreement was excellent for sPAP (ICC = 0.87). CONCLUSIONS: In a real-world, mixed-etiology PH cohort, TTE reliably identifies elevated pulmonary pressures but lacks precision for exact hemodynamic quantification. While valuable for screening, TTE cannot replace RHC for definitive diagnosis or hemodynamic classification, supporting a complementary diagnostic approach.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of echocardiographic hemodynamic assessment compared to right heart catheterization: results from the TECH prospective multicentric registryEuropean Heart Journal · 2026
- Echocardiography-led multimodal assessment for pulmonary hypertension in a right heart catheterization-referred cohort: incremental value of ECG and natriuretic peptides.Cardiovascular ultrasound · 2026
- Comparative accuracy of mean pulmonary artery pressure estimation using transthoracic echocardiography versus phase-contrast MRI in healthy adults.Quantitative imaging in medicine and surgery · 2026
- Impact of Thermodilution on Indexed Pulmonary Vascular Resistance Calculations in Pediatric Pulmonary Arterial Hypertension.Pediatric pulmonology · 2026
- Echocardiographic assessment of pulmonary hypertension: a hierarchical interpretive framework for clinical decision-making and echo laboratory practice.Echo research and practice · 2026
- Validation of Tricuspid Annular Displacement by Tissue Doppler in Pulmonary Hypertension.Pulmonary circulation · 2026