Validation of Tricuspid Annular Displacement by Tissue Doppler in Pulmonary Hypertension.
Rongrong Chen, Shadi P Bagherzadeh, Neev Patel, Patrick Khoury, Bettia E Celestin, Frida N Hermansson, Jennifer P Woo, Francois Haddad
Stanford Cardiovascular Institute Stanford University Stanford California USA. · Department of Nephrology Stanford University School of Medicine Stanford California USA.
Abstract
Tricuspid annular plane systolic excursion (TAPSE) is primarily measured using motion-mode (M-mode) echocardiography. However, image resolution doesn't always provide clear visualization. In these cases, tissue Doppler imaging (TDI) may offer a valuable alternative for right ventricular assessment. To validate TDI-derived TAPSE (TAPSE-TDI) against M-mode TAPSE and compare their diagnostic utility for right heart catheterization-confirmed pulmonary hypertension(PH). We analyzed 304 healthy volunteers and 310 PH patients in a case-control study. M-mode TAPSE and TAPSE-TDI were measured in the RV-focused apical four-chamber view. TAPSE-TDI was calculated by averaging the systolic and diastolic signals from the lateral tricuspid annulus. Agreement between methods was quantified using bias, percentile precision, and intra-class coefficient (ICC). The dependence of annular motion on body size, sex, and heart rate was evaluated with weighted regression. We assessed PH discrimination using receiver operating curve (ROC) analysis, comparing TAPSE, TAPSE-TDI, and RV TDI peak systolic velocity (s'). Thresholds were further tested using Classification and Regression Tree (CART) analysis. TAPSE-TDI demonstrated a strong linear relationship with TAPSE (r = 0.945, p < 0.001) and a slope of 1.02 in no-intercept regression. TAPSE-TDI demonstrated excellent reproducibility (ICC = 0.937), and its reference range fell within the guideline-recommended values. For PH diagnosis, TAPSE and TAPSE-TDI showed good discrimination (AUC > 0.83), with the TAPSE/RVSP ratio outperforming (both AUC > 0.96). CART analysis identified optimal thresholds of 16.68 mm for TAPSE and 15.88 mm for TAPSE-TDI to discriminate PH. TAPSE measured using TDI was closely related to M-mode and both better discriminated PH than RV s'.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reproducibility of Echocardiographic Measurements of Right Ventricular Function: Comparison Between TAPSE and TDI S′Journal of Cardiovascular Development and Disease · 2026
- Comprehensive comparison of echocardiographic and invasive hemodynamics in a real-world pulmonary hypertension cohort.Journal of echocardiography · 2026
- Right Ventricular-Pulmonary Artery Coupling by TAPSE/PASP in Tricuspid Regurgitation: A Narrative Review.Journal of cardiovascular development and disease · 2026
- Artificial Intelligence (AI)‐Facilitated Analysis of Single‐Image Tissue Doppler Signal to Characterize Right Ventricular DysfunctionEchocardiography · 2026
- Clinical Value of Real-Time Three-Dimensional Echocardiography for Evaluating Right Ventricular Structure and Function in Patients With Pulmonary Hypertension Across Different Echocardiographic Pulmonary Artery Systolic Pressure Strata.Echocardiography (Mount Kisco, N.Y.) · 2026
- Assessment of Right Atrial Function in Patients With Chronic Thromboembolic Pulmonary HypertensionEchocardiography · 2026