Periprocedural echocardiographic guidance for transcatheter paravalvular leak closure: from patient selection to follow-up.
Go Hashimoto, Yutsuki Tsukagoshi, Sari Waga, Yusuke Samejima, Kenji Makino, Hiroki Niikura, Hidehiko Hara
Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan. gou.hashimoto@med.toho-u.ac.jp. · Division of Cardiovascular Medicine, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro-ku, Tokyo, 153-8515, Japan.
Key points
From the paper's conclusion- The irregular and often complex anatomy of PVL requires imaging assessment throughout patient selection, procedural planning, device deployment, and follow-up.Transthoracic echocardiography assesses prosthetic valve function and the hemodynamic consequences of PVL.
Abstract
Paravalvular leak (PVL) after surgical valve replacement may cause heart failure, hemolytic anemia, or both. Transcatheter closure is an important therapeutic option for selected patients at high surgical risk. The irregular and often complex anatomy of PVL requires imaging assessment throughout patient selection, procedural planning, device deployment, and follow-up.Transthoracic echocardiography assesses prosthetic valve function and the hemodynamic consequences of PVL. Transesophageal echocardiography, particularly three-dimensional imaging with color Doppler, characterizes defect anatomy and guides wire crossing, device positioning, and release decisions. Assessment must address residual regurgitation, device stability, and potential interference with prosthetic valve function.Therapeutic goals depend on the dominant clinical phenotype. In heart failure-dominant PVL, sufficient reduction of regurgitant burden may improve symptoms and hemodynamics despite a small residual leak. In hemolysis-dominant PVL, residual high-velocity jets may sustain hemolysis and require additional closure. Mixed presentations require assessment of both hemodynamic and hematologic responses.Cardiac computed tomography complements echocardiography by defining channel geometry and fluoroscopic working projections, particularly when acoustic shadowing limits visualization. This review summarizes periprocedural echocardiographic assessment, emphasizing the integration of anatomical findings, clinical phenotype, and treatment response to guide procedural decisions and follow-up.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Successful Transcatheter Amplatzer Repair of Severe Paravalvular Leak Following Mechanical Mitral Valve Replacement Surgery.Case reports in cardiology · 2026
- Paravalvular Leak After Transcatheter Aortic Valve Implantation: Haemodynamic Consequences, Clinical Impact, and Contemporary Assessment.Journal of cardiovascular development and disease · 2026
- Intraprocedural echocardiographic guidance in transcatheter aortic valve implantation.Journal of cardiovascular imaging · 2026
- Von Willebrand Factor Biomarkers in Prosthetic Valve Dysfunction: An Adjunct to Imaging and Hemodynamic Assessment.Cardiology in review · 2026
- Effectiveness of intraprocedural guidance modalities on PFO closure outcomes: insights from the PROLONG registryEuropean Heart Journal · 2026
- Transcatheter Mitral Paravalvular Leak Closure With a Multifunctional Ventricular Septal Defect Occluder.JACC. Case reports · 2026