Metal-backed patella: a reasonable alternative in a bone-preserving approach in revision TKA.
Joshua L Tidd, Ignacio Pasqualini, Shlok V Patel, Shujaa T Khan, Khaled A Elmenawi, Viktor E Krebs, Nicolas S Piuzzi, Matthew E Deren
Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, US. · Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, US. piuzzin@ccf.org.
Key points
From the paper's conclusion- Titanium 3D-printed MBP resulted in excellent implant survivorship with major improvements in pain and overall joint health. Thus, MBP appears to be a viable patellar component option in revision TKA.
Abstract
INTRODUCTION: Patellar management during revision TKA (rTKA) remains challenging. Metal-backed patella (MBP) with highly porous titanium coating applied by 3D printing may provide improved fixation in TKA, especially in patients with limited bone stock. The primary aim of this study was to assess implant survivorship among patients who received a new-generation MBP during revision TKA. Secondary aims were to assess (1) healthcare utilization, and (2) preoperative and 1-year PROMs. METHODS: This was a retrospective review of patients who received a MBP during rTKA from 2017 to 2022. In total, 31 patients achieved an average follow-up of 3.0 years (SD 1.5 years). Knee injury and Osteoarthritis Outcome Score (KOOS) Pain, KOOS Physical Function Shortform (PS), KOOS Joint Replacement (JR) and Veterans RAND 12-Item Health Survey Mental Component Score (VR-12 MCS) were obtained preoperatively and at 1-year. Most patients had prior ipsilateral prosthetic joint infection (PJI; n = 22, 71%). RESULTS: MBP implant survivorship was 96.8%. No patients had evidence of patellar component aseptic loosening. The average patellar thickness was 11.8 mm (SD 2.3 mm). After rTKA, most patients were discharged home following surgery (n = 24, 77.4%). There were 5 patients (16.1%) readmitted within 90-days, and no deaths within 1-year. Significant improvement was found in KOOS Pain ( p< 0.001), and KOOS JR (p = 0.005), but not KOOS PS ( p= 0.080) or VR-12 MCS (p = 0.279). CONCLUSIONS: Titanium 3D-printed MBP resulted in excellent implant survivorship with major improvements in pain and overall joint health. Thus, MBP appears to be a viable patellar component option in revision TKA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patellar resurfacing in primary total knee arthroplasty is associated with fewer reoperations but comparable clinical and functional outcomes: an umbrella review of meta-analyses.Arthroplasty (London, England) · 2026
- Early Aseptic Tibial Loosening Following Cemented and Cementless Fixation of the Same Three-Dimensionally Printed Tibial Baseplate: A Consecutive Cohort of 1,214 Primary Total Knee Arthroplasties.The Journal of arthroplasty · 2026
- Cemented dual mobility component in newly implanted porous tantalum shells for severe acetabular defects: medium-term outcomes from a high-volume single-surgeon series.Archives of orthopaedic and trauma surgery · 2026
- Midterm Outcomes of Revision Total Hip Arthroplasty With Cementation of a Monoblock Dual-Mobility Bearing Cup in a Porous Revision Acetabular Shell.Arthroplasty today · 2026
- Radiographic Analysis of Bone Remodelling Around a Novel 3D-Printed, Highly Porous Titanium Monobloc Dual-Mobility Cup in Total Hip Arthroplasty at 2-Year Follow-Up.Biomimetics (Basel, Switzerland) · 2026
- Porous Tantalum Acetabular Components in Complex Revision Total Hip Arthroplasty: The Influence of Defect Severity and Intraoperative Fixation.The Journal of arthroplasty · 2026