Initial evaluation of a combined protocol using ultra-low-concentration iodinated contrast medium (140 mg I/mL) and low tube voltage for aortic CT angiography.
Shogo Tokurei, Kazuki Takegami, Yoichiro Ikushima, Masaki Takemitsu, Yoichiro Shimizu, Shohei Kudomi
Department of Radiological Science, Faculty of Health Sciences, Junshin Gakuen University, 1-1-1 Chikushigaoka, Minami-Ku, Fukuoka, 815-8510, Japan. stokurei@junshin-u.ac.jp. · Department of Radiological Technology, Yamaguchi University Hospital, Ube, Japan.
Key points
From the paper's conclusion- We evaluated a bundled aortic CT angiography protocol combining an ultra-low-concentration contrast medium (140 mg I/mL) with a low tube voltage (70 kVp).
Abstract
We evaluated a bundled aortic CT angiography protocol combining an ultra-low-concentration contrast medium (140 mg I/mL) with a low tube voltage (70 kVp). Fifty patients underwent this ultra-low-concentration protocol and 50 underwent a standard-concentration protocol (300-370 mg I/mL at 100 kVp). Attenuation and contrast-to-noise ratio (CNR) at seven aorto-iliac sites were compared using ANCOVA adjusted for body weight. Enhancement homogeneity was assessed using the within-patient standard deviation (SD) and proximal-to-distal attenuation decline, defined as ascending aortic attenuation minus mean attenuation of the common iliac arteries. The ultra-low-concentration protocol delivered less iodine despite a larger contrast volume. Unadjusted distal attenuation was lower but remained approximately 400 HU; after adjustment, attenuation did not differ significantly at any site. CNR and within-patient SD did not differ significantly, whereas the proximal-to-distal decline was greater. This bundled protocol reduced iodine load while providing approximately 400-HU aorto-iliac enhancement, although individual protocol effects could not be isolated.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Personalized low-iodine dual-layer spectral CT protocol for post-endovascular aortic repair imaging: a BMI/eGFR-adapted strategy preserving renal function, quality and diagnostic confidence.Clinical radiology · 2026
- Reduced contrast volume in coronary CT angiography: effects on coronary attenuationEgyptian Journal of Radiology and Nuclear Medicine · 2026
- Dose optimization in contrast-enhanced CT brain imaging using low tube voltage and reduced iodine concentration: a comparative study.BMC medical imaging · 2026
- Feasibility of omitting the unenhanced phase in CT angiography for acute aortic pathologies.PloS one · 2026
- Optimized dual-energy CT protocol for inferior vena cava CT angiography using 60 keV virtual monoenergetic imaging and 60% ASIR-V.Frontiers in cardiovascular medicine · 2026
- Prospective study to evaluate radiation dose and image quality in two-dimensional (2D) lower limb angiographic images acquired with a novel contrast-to-noise ratio (CNR)-driven exposure control protocol.Clinical radiology · 2026