Directional dependence of MRI geometric distortion under different receiver bandwidths.
Hayate Washio, Soichiro Tateishi, Makoto Shimada, Yuta Suzuki, Masaya Kobayashi, Yoshihiro Ueda, Yasuhiko Yamane, Nobuo Kashiwagi
Department of Radiology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 541-8567, Japan. washio-ha@oici.jp. · Department of Radiology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka, 541-8567, Japan.
Key points
From the paper's conclusion- Residual distortion varies among individual units and is not fully characterized by BW alone, supporting unit-level geometric QA.
Abstract
MRI residual geometric distortion compromises stereotactic body radiotherapy accuracy, but distortion magnitude, directional dependence, and bandwidth (BW) effects across individual units remain insufficiently understood. To evaluate the magnitude, spatial distribution, and directional characteristics of residual distortion across five clinical MRI units under multiple receiver-BW settings for unit-level quality assurance (QA). A 3D phantom was scanned on five 1.5T or 3T units (three vendors) at BWs of 200-1000 Hz/pixel with vendor 3D correction enabled. Absolute residual distortion and its x-, y-, and z-components were evaluated relative to isocenter. Whole-volume distortion generally decreased as BW increased, but was non-monotonic in central regions. Distortion increased with distance from isocenter, with dominant displacement axes (x-axis for Skyra, z-axis for Optima) differing among units. Residual distortion varies among individual units and is not fully characterized by BW alone, supporting unit-level geometric QA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A correction to the bandwidth difference method for assessment of magnetic resonance static field homogeneity.Medical physics · 2026
- Protocol optimization for quantitative MRI studies in radiation oncology: II. Diffusion MRIPhysics in Medicine and Biology · 2026
- Improved correction of anatomical distortion in diffusion-weighted prostate MRImedRxiv · 2026
- Does Denoising Reduce Cross-Vendor Variability in Diffusion MRI? A Travelling Heads EvaluationbioRxiv · 2026
- MRI Distortion Correction Produces Geometrically Relevant Shifts in Cisternal Trigeminal Nerve Localization: Implications for Gamma Knife Radiosurgery.Neuro-Chirurgie · 2026
- Bias-corrected respiratory motion standard deviation from amplitude-binned 4D-MRI for radiotherapy planning.Medical physics · 2026