Prevalence and utilization of insulin pump and continuous glucose monitoring data in Finnish forensic autopsies.
Paula Katriina Vauhkonen, Hilla Karjalainen, Petteri Oura
Department of Forensic Medicine, University of Helsinki, P.O. Box 21, Helsinki, FI-00014, Finland. paula.vauhkonen@helsinki.fi. · Forensic Medicine Unit, Finnish Institute for Health and Welfare, P.O. Box 30, Helsinki, FI-00271, Finland.
Key points
From the paper's conclusion- Our findings suggest non-systematic examination of insulin pumps and CGM data in current Finnish forensic cause-of-death investigation practices.
Abstract
Diabetes mellitus is a common metabolic condition with significance in the forensic context due to the associated risk for fatal dysglycemic events. In all deaths of individuals with diabetes, careful inspection of diabetes management devices is advisable, as they may provide invaluable insights into the circumstances preceding death. This study investigated the prevalence of insulin pumps and Continuous Glucose Monitoring (CGM) devices in Finnish forensic autopsies during the past decade and assessed their utilization in the cause-of-death investigation. Data was retrospectively extracted from a national electronic platform containing all forensic autopsy records 2016-2025, using predefined keyword searches targeted at diabetes, insulin pumps, and CGM devices. Cases were manually reviewed. We found records of 37 autopsied insulin pump cases (median age 41 years (range 18-72); 3.4% of all autopsied type 1 diabetics). Documentation about the insulin delivery system was variable. Cannula fixation was noted in 32.3% and pump history in 32.4% of the cases. The proportion of CGM-associated autopsies among all diabetic autopsies increased from 0.1% in 2016 to 4.1% in 2025, with a total of 352 autopsied CGM cases during the study period (median age 61 years (range 15-94)). CGM data was utilized in 9.1% of the associated cause-of-death investigations. Our findings suggest non-systematic examination of insulin pumps and CGM data in current Finnish forensic cause-of-death investigation practices. Education and standardized protocols for insulin pump examination and CGM data review are recommended to ensure quality and reliability in diabetes-related forensic cause-of-death investigations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A-360 Performance of rapid glucose and ketone screening methods in post-mortem vitreous fluid samples to determine ketoacidosis-mediated deathClinical Chemistry · 2026
- Multivendor Continuous Glucose Monitor Integration into the Electronic Health Record: Real-World Experience of an Academic Pediatric Endocrinology ClinicDiabetes Technology & Therapeutics · 2025
- Diagnosis and Management of Adult Type 1 Diabetes Mellitus: Systematic Reviews of Biomarkers, Insulin Regimens and Insulin Delivery Devices Highlighting Evidence Gaps in Emergency and Humanitarian Settings.Diabetes, obesity & metabolism · 2026
- Fingertip to sensor: The evolution of glucose monitoring technologies in type 1 diabetes and their implications for pediatric nursing care: Narrative review.Journal of pediatric nursing · 2026
- Inpatient continuous glucose monitoring halves the risk of hypoglycemia in patients with hyperinsulinism.Frontiers in endocrinology · 2026
- Continuous glucose monitoring-based care for adults with type 2 diabetes in community and ambulatory settings: a scoping review and evidence map of implementation pathwaysBMC Medicine · 2026