Clinic of Developmental Age Maxillofacial Surgery, Medical University of Silesia, Medyków 16, Katowice, 40-752, Poland. · Department of Computer Science, Faculty of Architecture, Civil Engineering and Applied Arts, Academy of Silesia, Rolna 43, Katowice, 40-555, Poland. bartosz.ignac@akademiaslaska.pl.
Key points
From the paper's conclusion- We compared whole-blood trace-element distributions in archived head and neck squamous cell carcinoma (HNSCC) and source-labelled comparison samples and audited the supporting records.
Abstract
We compared whole-blood trace-element distributions in archived head and neck squamous cell carcinoma (HNSCC) and source-labelled comparison samples and audited the supporting records. Complete panels comprised 36 HNSCC and 36 comparison records. Cd, Cu, Pb, and Zn were measured by atomic absorption spectrometry after open-vessel hot-nitric-acid digestion; Hg was measured separately by cold-vapor atomic absorption spectrometry. Analyses used Mann-Whitney tests, five-element false discovery rate (FDR) correction, Cliff's delta, bootstrap intervals, and conservative record exclusions. The HNSCC archive showed a higher Cd distribution (medians 0.320 vs. 0.2065 µg/L; FDR p = 1.03 × 10⁻⁴; δ = 0.584) and lower Zn distribution (4.795 vs. 5.398 mg/L; FDR p = 0.0125; δ = -0.367). Both persisted after conservative exclusions (33 HNSCC/34 comparison records; FDR p = 3.15 × 10⁻⁴ and 0.0237). Cu and Pb did not meet the FDR threshold. Hg contrasts varied by volume/block subset; the same-volume primary comparison had p = 0.0857. Recovered reference-material recoveries were 91.2-108.1%; blood-matrix validation was incomplete. Cd and Zn are descriptive archive-level observations. Comparator health and recruitment were unverified. Although the analyst reported shared non-Hg analytical cycles and calibrations, missing run-order and run-level QC records leave residual analytical confounding unresolved. Hg was additionally confounded by worksheet block and aliquot volume. These data do not establish disease-specific, causal, or diagnostic associations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Serum Trace Elements and Self-Reported Physician-Diagnosed Tumor History: A Secondary Cross-Sectional Analysis of the Exposure Study on Susceptible People (SPES).Medicina (Kaunas, Lithuania) · 2026
- Serum trace-element categories and reported first-degree family history of malignancy: an exploratory analysis of the SPES cohort.Frontiers in public health · 2026
- Serum and Plasma Zinc and Copper Levels in Oral Leukoplakia: A Systematic Review and Meta-Analysis.Antioxidants (Basel, Switzerland) · 2026
- Blood Metal and Volatile Organic Compound Mixture Patterns and Prevalent Cancer Among Adults with a Construction Occupational History: An Exploratory NHANES StudyPollutants · 2026
- Analytical Validation of a Multielement ICP-MS Method for Human Serum and Its Application to Trace Element Biomonitoring in Hemodialysis Patients.Toxics · 2026
- Joint association of cadmium exposure and inflammatory indicators with mortality in US cancer survivorsBMC Cancer · 2026