Initial experiences of surgical left atrial maze through resected left atrial appendage.
Takayuki Gyoten, Ritsushi Kato, Hitoshi Mori, Takahide Arai, Shintaro Nakano, Akihiro Yoshitake
Department of Cardiovascular Surgery, Saitama Medical University International Medical Center, 1397-1 Yamane, Hidaka, Saitama, 350-1298, Japan. t.gyoten29@gmail.com. · Department of Cardiology, Saitama Medical University International Medical Center, Saitama, Japan.
Key points
From the paper's conclusion- This technique is safe, simple, and provides acceptable freedom from recurrent atrial fibrillation, promising optimal survival. It can be perform with shorter cardiac arrest time and fewer complications and recommended as a concomitant procedure regardless of left atriotomy.
Abstract
OBJECTIVES: Despite high-level evidence support, the full Maze procedure remains underused because of complexity, prolonged arrest time, and training gaps. Therefore, we aimed to develop a simplified left atrial Maze procedure through the left atrial appendage. METHODS: All patients with permanent atrial fibrillation treated using this technique between January 2024 and February 2025 were enrolled. The technique comprised (1) bilateral pulmonary vein isolation, (2) appendage-to-roof ablation, (3) appendage ridge ablation, (4) mitral annulus ablation, (5) endocardial bottom line ablation, (6) epicardial bottom line ablation, and (7) inferior vena cava and tricuspid line ablation. Left atrial Maze was performed through an amputated left atrial appendage. All ablation lines were created using the AtricureRF (AtriCure, Inc., Cincinnati, Ohio, United States) and CryoICE (AtriCure, Inc., Cincinnati, Ohio, United States) devices. RESULTS: Among 17 patients, six and 11 underwent aortic valve surgery and coronary bypass grafting, respectively. Atrial fibrillation was classified as long-standing in 13 patients and persistent in four. Surgical ablation through the left atrial appendage was completed within 20 min of cardiac arrest. Overall survival and freedom from recurrent atrial fibrillation at 12-month follow-up were 94% and 86%, respectively. During follow-up, no patient required pacemaker implantation owing to new-onset complete atrioventricular block, and survivors had New York Heart Association Class I status. CONCLUSIONS: This technique is safe, simple, and provides acceptable freedom from recurrent atrial fibrillation, promising optimal survival. It can be perform with shorter cardiac arrest time and fewer complications and recommended as a concomitant procedure regardless of left atriotomy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biatrial Versus Left Atrial Maze Ablation During Cardiac Valve Surgery for Persistent Atrial Fibrillation: The ABLATION Trial.Circulation · 2026
- Feasibility, procedural efficiency, and early imaging outcomes of concomitant pulsed field ablation and left atrial appendage closure: a prospective single-centre studyEP Europace · 2026
- Pulsed field ablation for persistent atrial fibrillation with atrioventricular reentrant tachycardia under tubeless general anesthesia: a case report.AME case reports · 2026
- Surgical Treatment of Atrial Fibrillation.Circulation · 2026
- Left atrial appendage closure: Current status, unresolved issues, and future perspectivesCardiovascular Intervention and Therapeutics · 2025
- Atrial fibrillation in coronary artery bypass patients: what should be offered.Current opinion in cardiology · 2026