Pulsed field ablation for persistent atrial fibrillation with atrioventricular reentrant tachycardia under tubeless general anesthesia: a case report.
Weida Qiu, Xintong Wang, Shenrong Liu, Jianxing He, Ailan Chen
Department of Cardiology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China. · Department of Thoracic Surgery, China State Key Laboratory of Respiratory Disease & National Clinical Research Center for Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, China.
Key points
From the paper's conclusion- AVRT is a type of supraventricular tachycardia caused by the presence of an accessory pathway due to congenital structural abnormalities. Our case reports an AVRT occurrence during PFA for AF and provides significant evidence that PFA is effective and safe for accessory pathway ablation during AF ablation.
Abstract
BACKGROUND: Radiofrequency ablation (RFA) combined with left atrial appendage closure (LAAC) has long been used in the treatment of atrial fibrillation (AF). Pulsed field ablation (PFA) is now increasingly adopted due to its great precision and improved safety profile. This report presents a rare case of PFA performed for persistent AF and atrioventricular reentrant tachycardia (AVRT), along with LAAC, under non-intubated general anesthesia. CASE DESCRIPTION: A 36-year-old male patient presented with a 10-year history of recurrent chest tightness and palpitations, which had worsened during the week prior to admission. He was diagnosed with dilated cardiomyopathy and AF 4 months ago and had a previous cerebral infarction, with a CHA2DS2-VASc score of 3 and a HAS-BLED score of 1. A one-stop procedure combining PFA and LAAC was planned. During ablation at the roof of the right superior pulmonary vein, AF converted to sinus rhythm and subsequently developed spontaneous tachycardia, suspected to be AVRT due to a left-sided accessory pathway near CS1-2. Therefore, ablation of the accessory pathway and mitral isthmus was performed, and atrioventricular separation and mitral isthmus block were confirmed. A total of 78 discharges were delivered throughout the procedure, and repeated high-frequency atrial stimulation did not induce atrial flutter or AF. LAAC was then completed as planned. Electrocardiogram (ECG) showed sinus rhythm, and echocardiography demonstrated improved cardiac remodeling at 3-month follow-up. CONCLUSIONS: AVRT is a type of supraventricular tachycardia caused by the presence of an accessory pathway due to congenital structural abnormalities. Our case reports an AVRT occurrence during PFA for AF and provides significant evidence that PFA is effective and safe for accessory pathway ablation during AF ablation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pulsed Field Ablation for Atrial Fibrillation in Australia: A Large Tertiary Centre Analysis.Heart, lung & circulation · 2026
- Standalone PFA for Complex Macro-Reentrant and Fibrillatory Substrates following Mustard-Atrial Switch.Indian pacing and electrophysiology journal · 2026
- Feasibility, procedural efficiency, and early imaging outcomes of concomitant pulsed field ablation and left atrial appendage closure: a prospective single-centre studyEP Europace · 2026
- Pulmonary Vein Isolation Using Pulsed Field Ablation With vs Without Posterior Wall Isolation in Patients With Symptomatic Persistent Atrial Fibrillation: The PIFPAF-PFA Randomized Clinical Trial.JAMA · 2026
- Atrial Fibrillation Ablation in a Patient with Partial Anomalous Pulmonary Vein.The Journal of innovations in cardiac rhythm management · 2026
- Treatment of paroxysmal and persistent atrial fibrillation with pulsed field ablation.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026