Public disclosure and traceability of FDA-cleared remanufactured da Vinci instruments: a model-level documentary audit, 2022-2026.
Logan Glosser, Quynh Tran, Tucker Bettis, Felipe Maegawa, Snehal Patel
Emory University School of Medicine, Atlanta, GA, USA. · Emory University School of Medicine, Atlanta, GA, USA. snehal.patel@emory.edu.
Key points
From the paper's conclusion- From public records, surgical teams can confirm which remanufactured instruments are cleared but not how far their added life has been tested or which device a surveillance report concerns.
Abstract
The US Food and Drug Administration (FDA) has cleared remanufactured da Vinci instruments for additional uses since 2022. We assessed what public records disclose about each model's intended lifetime, the testing cited for added uses, and its identity in surveillance. Cross-sectional documentary audit of all eight 510(k) clearances under product code QSM (nine models) through 22 October 2026. Each summary was coded across ten validation domains (90 cells) and linked to original equipment manufacturer (OEM) policy-page versions, securities filings, court records, and FDA adverse-event reports. Two language-model-assisted coding passes were compared, adjudicated, and verified by an author against source documents. Every numeric life-extension claim (ten added uses; four models) applied to a monopolar energy instrument, yet no summary reported a test sample size, cycle exposure, acceptance criterion, or electrical-safety result, or the original labeled use count. Six of eight clearances cited another clearance for test methods, forming three documented lineages. The OEM policy page first listed cleared models in March 2025, 897-929 days after the first clearance. All 26 adverse-event reports identified concerned scissors; 23 were notifications attributed to the OEM (one named, 21 inferred), 23 carried the OEM product code, and one a cohort model number. No applicant held a unique device identifier record. From public records, surgical teams can confirm which remanufactured instruments are cleared but not how far their added life has been tested or which device a surveillance report concerns. A ten-item model-level verification record would support procurement, sterile processing, point-of-use review, and surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reporting of procedural information and data access in surgical robotics across four specialties.Journal of robotic surgery · 2026
- Post-market safety signals of energy-based surgical devices: a cross-specialty disproportionality analysis of the FDA MAUDE database with robotic-platform validation and regulatory triangulation, 2015-2025.Journal of robotic surgery · 2026
- Perioperative adverse events and device malfunctions associated with ROSA cranial stereotactic robotic surgery a descriptive analysis of FDA MAUDE reports from 2016 to 2026.Journal of robotic surgery · 2026
- A health systems governance framework for verifying medical device recall completionDiscover Health Systems · 2026
- Federated Bayesian Surveillance of Mechanical Thrombectomy Adverse Events: A Population Risk Layer for Surgical Digital TwinsarXiv · 2026
- Laparoscopic and Robotic Device Malfunction: A Scoping Review.Journal of patient safety · 2026