Precision in achieving planned HKA alignment using a hybrid method of resection in imageless robot assisted total knee arthroplasty: a retroprospective study of 103 knees.
Pratik M Rathod, Sivakumar Raju, Arul Prakash Nehru, Varun Vasudevan, Rajesh Naik, Prahalad Kumar Singhi, Nissant Chandrasekaran
Division of Robotics and Joint Replacement, Department of Orthopaedics, Preethi Hospitals Pvt Ltd, Madurai, Tamil Nadu, India. Pratik3800@gmail.com. · Division of Robotics and Joint Replacement, Department of Orthopaedics, Preethi Hospitals Pvt Ltd, Madurai, Tamil Nadu, India.
Key points
From the paper's conclusion- We retrospectively reviewed 85 patients (103 knees) from 264 consecutive primary TKAs performed with the imageless hand-held robot (CORI) system at a single center between September 2024 and August 2025.
Abstract
Evidence on hybrid robotic-resection workflows in robotic-assisted TKA is limited. This study quantified agreement between planned, intraoperatively achieved, and early postoperative standing hip-knee-ankle (HKA) alignment using a hybrid resection workflow with the CORI system. We retrospectively reviewed 85 patients (103 knees) from 264 consecutive primary TKAs performed with the imageless hand-held robot (CORI) system at a single center between September 2024 and August 2025. The distal femur was resected and the proximal tibia refined with the burr, and the remaining femoral cuts were made with a conventional 4-in-1 jig. HKA was measured preoperatively, as planned, and as achieved intraoperatively after resections with trials and on full-length weight-bearing radiographs at 3 weeks. Forgotten joint score (FJS 12) was recorded at 6 months. Agreement was assessed using mean signed error, RMSE, and 95% confidence intervals, and measurement reliability using ICC for inter and intra-observer variations. The cohort comprised 85 patients (103 knees; 67 unilateral, 18 bilateral). Mean preoperative HKA was 166.1° ± 6.7° and improved to 177.8° ± 1.9° on early postoperative standing radiographs. Planned HKA was 178.8° ± 0.8° and intraoperatively achieved HKA was 178.0° ± 1.6°, a mean signed error of - 0.8° ± 1.3° (95% CI), indicating slight under-correction relative to plan. RMSE was 1.50° (planned vs achieved), 2.17° (planned vs postoperative), and 1.98° (achieved vs postoperative). Mean FJS 12 at 6 months was 76.0 ± 11.8 (range 54-95) Measurement reliability (inter and intra observer) was good to excellent (ICC 0.89-0.98).In this retrospective series, the hybrid CORI workflow showed close agreement between planned, intraoperatively achieved, and early postoperative standing HKA, with a small mean under-correction of 0.8° relative to plan. These findings are descriptive; without a comparator or long-term clinical outcomes, they cannot establish equivalence to fully robotic or conventional TKA. Prospective comparative studies are needed to evaluate the comparisons.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Imageless robotic assistance versus laser-projected mechanical-axis guidance in total knee arthroplasty: a deformity-stratified comparative cohort study.Journal of robotic surgery · 2026
- Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study.Journal of clinical medicine · 2026
- Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective AnalysisLife · 2026
- Does Robotic Assistance Improve Restoration of Coronal Plane Alignment of the Knee in Kinematically Aligned Total Knee Arthroplasty? A Comparative Alignment Study.Journal of orthopaedics · 2026
- Radiographic Alignment Control and Joint Line Preservation With Robotic-Assisted Versus Manual Total Knee Arthroplasty in Valgus Knees.The Journal of arthroplasty · 2026
- Improved surgical accuracy in total knee arthroplasty using the ROSA® knee system: A randomised‐controlled unblinded trialKnee Surgery Sports Traumatology Arthroscopy · 2025