Does Robotic Assistance Improve Restoration of Coronal Plane Alignment of the Knee in Kinematically Aligned Total Knee Arthroplasty? A Comparative Alignment Study.
Jeremy Tze En Lim, Yong Ng, Jia Wei Chen, Ren Yi Kow, Hee Nee Pang, Darren Keng Jin Tay, Seng Jin Yeo, Ming Han Lincoln Liow
Department of Orthopedic Surgery, Singapore General Hospital, Singapore. · Department of Orthopedic Surgery, Traumatology and Rehabilitation, International Islamic University Malaysia Sultan Ahmad Shah Medical Center, Pahang, Malaysia.
Key points
From the paper's conclusion- Robotic KA-TKA improved tibial alignment precision and reduced joint-line obliquity deviation but did not increase CPAK phenotype restoration compared with conventional KA-TKA. These findings suggest that coronal phenotype preservation depends on combined femoral-tibial alignment rather than isolated component accuracy.
Abstract
OBJECTIVES: To compare Coronal Plane Alignment of the Knee (CPAK) phenotype restoration and component alignment accuracy between robotic-assisted and conventional calipered kinematically aligned total knee arthroplasty (KA-TKA). MATERIAL AND METHODS: A retrospective comparative study of 319 primary KA-TKAs (127 robotic, 192 conventional) performed between 2020 and 2024 was conducted. Pre- and six-week postoperative weight-bearing long-leg radiographs were used to determine arithmetic hip-knee-ankle angle (aHKA), joint-line obliquity (JLO), and CPAK phenotype. CPAK transitions were classified as restoration, aHKA-driven change, JLO-driven change, or non-favorable shift. Alignment accuracy of the femoral component (lateral distal femoral angle, LDFA) and tibial component (medial proximal tibial angle, MPTA) within ±3° of the target was compared. RESULTS: Baseline characteristics were comparable between groups, apart from slightly higher age in the robotic cohort. CPAK restoration rates were similar (52.6% vs 52.8%, p = 1.000). aHKA-driven changes occurred in 30.2% versus 22.0% (p = 0.447), while JLO-driven changes were less frequent in the robotic group (15.1% vs 24.4%, p = 0.053). Robotic assistance improved tibial alignment accuracy (80.3% vs 68.2%, p = 0.024), whereas femoral alignment accuracy was similar (85.0% vs 83.9%, p = 0.898). CONCLUSION: Robotic KA-TKA improved tibial alignment precision and reduced joint-line obliquity deviation but did not increase CPAK phenotype restoration compared with conventional KA-TKA. These findings suggest that coronal phenotype preservation depends on combined femoral-tibial alignment rather than isolated component accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The impact of changing Coronal Plane Alignment of the Knee classification on early functional outcomes after primary robotic-assisted total knee arthroplasty.The bone & joint journal · 2026
- Differences in the coronal plane alignment of the knee (CPAK) measurements using long-leg radiographs and computed tomography.Archives of orthopaedic and trauma surgery · 2026
- Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective AnalysisLife · 2026
- Radiographic Alignment Control and Joint Line Preservation With Robotic-Assisted Versus Manual Total Knee Arthroplasty in Valgus Knees.The Journal of arthroplasty · 2026
- Robotic-assisted total knee arthroplasty: radiological precision, clinical outcomes, and benchmarks for emerging systems.Journal of robotic surgery · 2026
- Kinematical-aligning of femoral component decreases overstuffing of lateral distal condyle and provides better patellar tracking and postoperative outcomes in robotic-assisted total knee arthroplasty.Journal of robotic surgery · 2026