Technical feasibility of AI-based longitudinal multi-organ volumetry on low-dose PET/CT over 13 years.
Rika Kobayashi, Tetsuro Sekine, Shogo Imai, Koji Sohara, Takahiro Ando, Aruki Tanaka, Nahiro Yan, Hiromitsu Hayashi,
Department of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan. · Department of Radiology, Nippon Medical School, 1-1-5 Sendagi, Bunkyo-Ku, Tokyo, 113-8603, Japan. tetsuro.sekine@gmail.com.
Key points
From the paper's conclusion- Fast mode on raw low-dose PET/CT provided the most favorable speed-stability trade-off for TotalSegmentator-based multi-organ volumetry. Long-term within-participant volumetric trends were detectable over a 13-year follow-up, supporting technical feasibility but not yet establishing biological attribution or clinical utility.
Abstract
PURPOSE: This study aimed to (i) compare TotalSegmentator Fast and Normal inference modes on low-dose PET/CT, (ii) evaluate whether CT denoising improves segmentation longitudinal consistency, and (iii) examine whether the selected pipeline can capture long-term within-participant volumetric trends over approximately 13 years. MATERIALS AND METHODS: This retrospective study drew from a PET/CT screening registry of 15,597 examinees. In Phase 1, 10 participants (137 scans) were selected for pipeline optimization: Fast versus Normal modes and five denoising methods were compared using detrended within-participant CV. In Phase 2, 30 participants aged ≥60 years (337 scans) were analyzed. Volumetric changes in six structures were modeled using a linear mixed-effects model with false discovery rate correction. RESULTS: Fast mode demonstrated similar detrended longitudinal variability to Normal mode across the six analyzed structures (detrended CV range: 2.26-9.32%), with approximately 10-fold faster processing. No tested denoising method meaningfully improved the selected serial-variability metrics over raw CT. In the primary random-intercept model, all six structures showed significant population-average volumetric trends (all p < 0.001, FDR q < 0.001): autochthon (paraspinal) muscles (- 0.72%/year), iliopsoas (- 0.74%/year), liver (- 0.55%/year), kidneys (- 0.49%/year), pancreas (- 0.97%/year), and aorta (+ 0.94%/year). In the random-slope sensitivity analysis, all six structures-including the iliopsoas and aorta-remained statistically significant (all RS p < 0.01) when individual trajectory slopes were accommodated. CONCLUSION: Fast mode on raw low-dose PET/CT provided the most favorable speed-stability trade-off for TotalSegmentator-based multi-organ volumetry. Long-term within-participant volumetric trends were detectable over a 13-year follow-up, supporting technical feasibility but not yet establishing biological attribution or clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep-learning body composition analysis of routine CT robust to scan range, slice order and contrast phasemedRxiv · 2026
- Quantifying [18F]FDG Uptake in the Liver, Spleen, Aorta, Bone Marrow, and Superior Vena Cava Using TotalSegmentator on [18F]PET/CT Imaging.Diagnostics (Basel, Switzerland) · 2026
- AI-based automated body composition analysis from whole-body MRI and (PET-) CT: an intermodal comparison from same-day examinations.Cancer imaging : the official publication of the International Cancer Imaging Society · 2026
- Meta-PET: A graininess-modulated test-time adaptive network for low-count PET denoising.Medical image analysis · 2026
- AutoLMISeg: A Fully Automated Pipeline for 3D Lumbar Muscle Volumetry and Densitometry on CT - Technical Validation Against an Operator-Driven Workflow.Journal of imaging informatics in medicine · 2026
- Extending TotalSegmentator: Predicting Patient and Acquisition Characteristics from CT and MR ImagesarXiv · 2026