International journal of computer assisted radiology and surgery

Quantifying inter-surgeon variation in computed tomography-based preoperative planning for total hip arthroplasty.

Ryo Higuchi, Keisuke Uemura, Kazuma Takashima, Tomoki Asano, Sotaro Kono, Masaya Sakamoto, Hirokazu Mae, Kazunori Tamura,

Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, Japan. · Department of Orthopaedic Medical Engineering, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan. surmountjp@gmail.com.

Computational

Key points

From the paper's conclusion
  • Inter-surgeon variation assessed by MPD provided a direct measure of the absolute magnitude of differences among surgeons' plans. Our findings demonstrate that noticeable inter-surgeon variation exists in preoperative THA planning despite high agreement coefficients. Quantitative benchmarks derived from these data may be useful for evaluating planning consistency and for validating emerging technologies, including artificial intelligence-based automated THA planning systems.

Abstract

PURPOSE: Three-dimensional (3D) preoperative planning is essential in total hip arthroplasty (THA) to optimize implant alignment and reduce the risk of impingement-related complications such as dislocation. Although recent technological advances, including computed tomography (CT)-based navigation and robotic-assisted surgery, have improved the accuracy of implant placement, variation in preoperative planning among surgeons remains poorly understood. This study aimed to quantify inter-surgeon variation in 3D preoperative THA planning and to evaluate the impact of stem design on this variation. METHODS: Eleven hip surgeons independently performed 3D preoperative planning for 50 THA cases using a CT-based planning system. The cases included two stem types: tapered wedge stems and anatomical stems. Implant size was fixed, and planning was performed according to the combined anteversion theory. Inter-surgeon variation in implant orientation and position was quantified using the mean pairwise absolute difference (MPD) and intraclass correlation coefficients (ICC). The surgeon-selected cup-stem anteversion combinations were grouped into five categories, and inter-surgeon agreement was assessed using Fleiss' kappa coefficient. RESULTS: Angular MPDs ranged from 0.8° to 3.8°, with the greatest variation observed in stem anteversion. Positional MPDs ranged from 0.8 to 2.1 mm, with the largest variation observed along the stem craniocaudal axis. The ICCs ranged from 0.69 to 0.99. Agreement in cup-stem anteversion categories was moderate (kappa = 0.44). When the two stem groups were compared, no significant differences in angular variation were observed, while only limited differences in positional variation were found. CONCLUSION: Inter-surgeon variation assessed by MPD provided a direct measure of the absolute magnitude of differences among surgeons' plans. Our findings demonstrate that noticeable inter-surgeon variation exists in preoperative THA planning despite high agreement coefficients. Quantitative benchmarks derived from these data may be useful for evaluating planning consistency and for validating emerging technologies, including artificial intelligence-based automated THA planning systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Quantifying inter-surgeon variation in computed tomography-based preoperative planning for total hip arthroplasty — Science Skim